DP40
40 Watts
Special Features
• Medical and ITE safeties
• Universal AC input
• Fully regulated output
• Overload and short circuit
• Constant voltage
• High efficiency
• High MTBF
• IEC320 AC input receptacle
3 pin (type C14)
2 pin (type C8)
• Built in EMI filter
• LED power good indicator
• Input power < 49 watts
• Complies with EN61000-3-2
• Meets Energy Star 2.0
• WEEE & CeC IV compliant
• CE Mark EMC & LVD
• Less than 300 mW No-Load
Safety
•
•
•
•
•
•
Total Power:
Input Voltage:
# of Outputs:
protection
(CISPR 22 Class B)
power consumption
UL
cUL
TUV 60950-1, 60601-1
CE
CB
CCC China Approval
60950-1, 60601-1
60950-1, 60601-1
EMC & LVD
Certificate and report
40 Watts
90 - 264 VAC
127 - 300 VDC
Single
Environmental Specifications
Electrical Specifications
Input
Frequency:
Inrush current:
Input current:
Efficiency:
EMI/RFI:
Safety ground
leakage current:
Output
Maximum Power (Po):
Hold-up time:
Overvoltage protection:
Overload protection:
Cable/connector:
Operating temperature:
Storage temperature:
Electromagnetic
susceptibility:
Humidity:
Vibration:
MTBF demonstrated:
Input range:
90 - 264 Vac (wide range)
127 - 300 Vdc
47 - 63 Hz
< 50A @ 230 Vac, cold start @ 25 °C
< 0.5 A rms @ 115 Vac; < 0.25 A @ 230 Vac
84% @ full load typical, @115 Vac
FCC Part 15, Subpart B Class B & EN55022 (CISPR 22) Class B
40 W
10 ms. typical at full load @ 115 Vac
20% - 45% above nominal output maximum
Latching type, recycle AC to reset.
Output short circuit protection auto recover
Overload protected @ 110 - 160% above peak rating
1.2 m DC cable with 2.5mm I.D, 5.5 mm O.D center plug
DC plug center +v
DC plug outer -v
0 ° to +40 °C ambient. Derate each output as 2.5% per degree from
40 °C to 60 °C. -20 °C start up
-40 °C to +85 °C
Designed to meet EN61000-4, -2, -3, -4, -5, -6, -8, -11, Level 3
Operating; non-condensing 10% to 90% RH
Three orthogonal axes, 3 sweeps per axe at 1 oct/min. 2G peak 8Hz
to 500Hz, operational
> 550,000 hours at full load and 25 °C ambient conditions
300 µA @ 50/60 Hz, 264 Vac input for 3 pin model
100 µA @ 50/60 Hz, 264 Vac input for 2 pin model
Embedded Power for
Business-Critical Continuity
Rev. 9.23.09_75
DP40
of 2