AS5163 CB austriamicrosystems, AS5163 CB Datasheet - Page 31

no-image

AS5163 CB

Manufacturer Part Number
AS5163 CB
Description
BOARD CONNECTION AS5163
Manufacturer
austriamicrosystems
Datasheets

Specifications of AS5163 CB

Accessory Type
Interface Board
For Use With/related Products
AS5000, AS5163-AB, AS6263-PB
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
AS5163
Datasheet - A p p l i c a t i o n I n f o r m a t i o n
8.2.3 Physical Placement of the Magnet
The best linearity can be achieved by placing the center of the magnet exactly over the defined center of the chip as shown in
Figure
26.
Figure 26. Defined Chip Center and Magnet Displacement Radius
3.2mm
3.2mm
1
Defined
center
R
d
Area of recommended maximum magnet
misalignment
8.2.4 Magnet Placement
The magnet’s center axis should be aligned within a displacement radius R
of 0.25mm (larger magnets allow more displacement) from the
d
defined center of the IC.
The magnet may be placed below or above the device. The distance should be chosen such that the magnetic field on the die surface is within
the specified limits
(see Figure
26). The typical distance “z” between the magnet and the package surface is 0.5mm to 1.5mm, provided the
recommended magnet material and dimensions (6mm x 3mm) are used. Larger distances are possible, as long as, the required magnetic field
strength stays within the defined limits.
However, a magnetic field outside the specified range may still produce usable results, but the out-of-range condition will be indicated by an
alarm forcing the output into the failure band.
Figure 27. Vertical Placement of the Magnet
N
S
Package surface
Die surface
www.austriamicrosystems.com/AS5163
Revision 2.7
31 - 36

Related parts for AS5163 CB