CMOD232+ Maxim Integrated Products, CMOD232+ Datasheet - Page 8

no-image

CMOD232+

Manufacturer Part Number
CMOD232+
Description
EVAL SYSTEM FOR MAX9850
Manufacturer
Maxim Integrated Products
Datasheets

Specifications of CMOD232+

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Provided Clock selection. Depending on the desired
mode of operation (see the MAX9850 Mode Setup sec-
tion) digital audio data can be synchronized to the
master clock signal. The on-board S/PDIF receiver per-
forms the synchronization of the digital audio data to
the chosen MAX9850 master clock signal. To synchro-
nize the digital audio to the MAX9850 master clock,
check the Synchronize Data with Clock checkbox.
Note: When using the Recovered Master Clock as the
master clock frequency, the digital audio data will
always be synchronized.
The MAX9850 uses a frequency-divided master clock
signal throughout the IC (see the MAX9850 Mode
Setup section). Select the desired internal clock-divider
ratio from the Internal Clock Divide Ratio pulldown.
The MAX9850 EV kit software is capable of calculating
the master clock, internal clock, and charge-pump
clock frequencies. Press the Update Clocks in Status
Bar button to display the calculated values. Checking
the Automatically Update Clocks checkbox will
update the calculated values on a regular basis.
The MAX9850 Mode Setup window alters its appear-
ance depending on which mode is selected. Figures
6–9 show the different appearances of these windows.
Both Master (Non-Integer) and Master (Integer)
modes of the MAX9850 EV kit software (Figures 6 and
MAX9850 Evaluation System/Evaluation Kit
Figure 6. Master (Non-Integer) Mode
8
_______________________________________________________________________________________
MAX9850 Mode Setup
7) are similar in operation. Select Manual Control to
write directly to the MAX9850 registers. Enter the num-
ber in the MSB/LSB edit box in Master (Non-Integer)
and LSB in Master (Integer) mode and press the
Update button to write to the MAX9850. Alternatively,
the Automatic mode can be selected and a desired
Figure 7. Master (Integer) Mode
Figure 8. Slave (Non-Integer) Mode