MCP3909RD-3PH3 Microchip Technology, MCP3909RD-3PH3 Datasheet - Page 42

no-image

MCP3909RD-3PH3

Manufacturer Part Number
MCP3909RD-3PH3
Description
REF DESIGN FOR MCP3909 W/18F2520
Manufacturer
Microchip Technology

Specifications of MCP3909RD-3PH3

Main Purpose
Power Management, Energy/Power Meter
Utilized Ic / Part
MCP3909, PIC18F2520, PIC18F4550
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Secondary Attributes
-
Embedded
-
Primary Attributes
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
MCP3909 / dsPIC33F 3-Phase Energy Meter Reference Design
DS51723A-page 42
4.4.1
The process of phase calibration is as follow:
1. Setup input condition: Phase A, voltage input 220V, current input is the current
2. Load the dsPIC33F with the proper correction factors. This is automatically done
3.
4. Repeat for Phases B & C.
Note:
for region 1, voltage and current inputs of phase B and phase C are zero.
using the PC software. See Chapter 5. “PC Software”.
phase A.
Repeat steps 1 and 2 for phase lag calibrations for all current regions of
Phase Lag Calibration Process
If the power metering error still can not meet the requirement, the meter can
be calibrated a few more times. When doing so, simply input a new error
value into the front-end of the meter.
© 2009 Microchip Technology Inc.