SI2457FS18-EVB Silicon Laboratories Inc, SI2457FS18-EVB Datasheet - Page 2

no-image

SI2457FS18-EVB

Manufacturer Part Number
SI2457FS18-EVB
Description
BOARD EVAL SI2457 + SI3018 16PIN
Manufacturer
Silicon Laboratories Inc
Series
ISOmodem®r
Datasheets

Specifications of SI2457FS18-EVB

Main Purpose
Telecom, Data Acquisition Arrangement (DAA)
Utilized Ic / Part
Si2457
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Secondary Attributes
-
Embedded
-
Primary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Global ISOmodem-EVB
1. Si2493/57/34/15/04-EVB Setup and
This section explains how to set up the Si2493/57/34/
15/04-EVB for evaluation as an RS-232 or USB
interface modem. Jumper settings, power connection,
PC/terminal
configuration settings are given. The initial modem
setup after power is applied as well as a basic tutorial
on modem operation are provided. Si2493/57/34/15/04-
EVB configurations for evaluating additional features
are discussed separately. See the Si2493/57/34/15 or
Si2404 data sheets and “AN93: Si2493/57/34/15/04/04
Modem Designer’s Guide” for complete details.
1.1. Si2493/57/34/15/04-EVB Quick Start—
1. Set jumpers according to Figure 1 or Figure 2.
2. Connect:
3. Bring up:
4. Type “AT” followed by a carriage return.
2
protocol.
Evaluation
Autobaud automatically adjusts modem DTE speed and
DB-9 to PC COM 1 (with a pass-through cable).
RJ-11 to phone line or test box.
9 V ac adaptor (or USB cable).
Turn on power to modem.
Should echo “AT” and then an “OK”.
RS-232 Interface
Figure 1. Standard Factory Jumper Settings—RS-232 Interface (Outlined in Gray) (FT Option)
connections,
and
terminal
program
Rev. 0.6
1.2. Si2493/57/34/15/04-EVB Quick Start—
1. Set jumpers according to Figure 3 or Figure 4.
2. Connect:
3. Download USB driver for your operating system from the
4. Install driver.
5. Bring up.
6. Type “AT” followed by a carriage return.
1.3. Jumper Settings
Check all jumper settings on the Si2493/57/34/15/04-
EVB before applying power. The standard factory
jumper settings for the FT package are shown in
Figure 1; the FS package is shown in Figure 2. These
settings configure the Si2493/57/34/15/04-EVB for RS-
232 serial operation with autobaud. Any standard
terminal program configured to communicate through a
PC COM port can be used to communicate with the
Si2493/57/34/15/04-EVB. The standard factory jumper
settings for USB operation with the FT package are
shown in Figure 3; the FS package is shown in Figure 4.
The only difference between RS-232 and USB jumper
settings is that JP5 must be installed to enable USB.
CD supplied with the evaluation board.
protocol.
Autobaud automatically adjusts modem DTE speed and
USB cable to PC
RJ-11 to phone line or test box
Reset the modem.
Should echo “AT” and then an “OK”.
USB Interface

Related parts for SI2457FS18-EVB