RDK-138 Power Integrations, RDK-138 Datasheet - Page 11

KIT REF DESIGN 1.2W PS TN FAMILY

RDK-138

Manufacturer Part Number
RDK-138
Description
KIT REF DESIGN 1.2W PS TN FAMILY
Manufacturer
Power Integrations
Datasheets

Specifications of RDK-138

Mfg Application Notes
LinkSwitch-TN Design Guide, AN-37
Main Purpose
AC/DC, Non-Isolated
Outputs And Type
2, Non-Isolated
Power - Output
1.2W
Voltage - Output
12V, 5V
Current - Output
80mA, 50mA
Voltage - Input
85 ~ 265VAC
Regulator Topology
Buck
Frequency - Switching
66kHz
Board Type
Fully Populated
Utilized Ic / Part
LNK304
Product
Accessories & Kits
Lead Free Status / RoHS Status
Not applicable / Not applicable
Other names
596-1197
7 Performance Data
All measurements performed at room temperature, 60 Hz input frequency.
7.1 Efficiency
7.1.1 Active Mode CEC Measurement Data
All single output adapters, including those provided with products, for sale in California
after July 1
minimum active mode efficiency and no load input power.
efficiency is defined as the average efficiency of 25, 50, 75 and 100% of rated output
power with the limit based on the nameplate output power:
Page 11 of 28
60.0%
58.0%
56.0%
54.0%
52.0%
50.0%
48.0%
46.0%
44.0%
42.0%
40.0%
25%
st
Nameplate Output (P
, 2008, must meet the California Energy Commission (CEC) requirement for
≥ 1 W to ≤ 49 W
Figure 4 – Efficiency vs. Output Power, Room Temperature, 60 Hz.
> 49 W
< 1 W
O
50%
)
Efficiency vs. Load
Minimum Efficiency in Active Mode of Operation
Load Percent
0.09 × ln (P
O
Tel: +1 408 414 9200 Fax: +1 408 414 9201
75%
) + 0.50 [ln = natural log]
0.50 × P
0.85
O
Minimum active mode
Power Integrations
www.powerint.com
100%
115 VAC
230 VAC

Related parts for RDK-138