RDK-91 Power Integrations, RDK-91 Datasheet - Page 20

KIT DESIGN REF TINYSWITCH-III

RDK-91

Manufacturer Part Number
RDK-91
Description
KIT DESIGN REF TINYSWITCH-III
Manufacturer
Power Integrations
Series
TinySwitch®-IIIr
Datasheets

Specifications of RDK-91

Main Purpose
AC/DC, Primary Side
Outputs And Type
1, Non-Isolated
Power - Output
12W
Voltage - Output
12V
Current - Output
1A
Voltage - Input
85 ~ 265VAC
Regulator Topology
Flyback
Board Type
Fully Populated
Utilized Ic / Part
TNY274, TNY275, TNY276, TNY277, TNY278, TNY279, TNY280
Product
Accessories & Kits
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Frequency - Switching
-
Other names
596-1194
9.2 Active Mode CEC Measurement Data
In the state of California, after July 1, 2006, all single-output EPS adapters – including
those sold with the products they power – must meet the California Energy Commission
(CEC) requirement for minimum active-mode efficiency and no-load input power
consumption. Minimum active-mode efficiency is defined as the average efficiency at 25,
50, 75 and 100% of rated output power printed on the nameplate of the supply:
For adapters that are single input voltage only, the measurements are to be made at the
nominal rated input voltage (115 VAC or 230 VAC). For universal input adapters, the
measurements are to be made at both nominal input voltages (115 VAC and 230 VAC).
To comply with the standard, the average of the four efficiency measurements must be
greater than or equal to the efficiency specified by the standard.
From these results it is apparent that the efficiency of this design easily exceeds the
required 71.3 %. More states within the USA, and many other countries around the world
are adopting similar energy efficiency standards (based on the original Energy Star
standard). For the latest, up-to-date information on energy efficiency regulations, please
visit the PI Green Room, at:
Power Integrations
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com
Nameplate Output (P
≥ 1 W to ≤ 49 W
> 49 W
http://www.powerint.com/greenroom/regulations.htm
< 1 W
minimum average
Percent of Full
Required CEC
efficiency (%)
O
Average
)
Load
100
25
50
75
Minimum Efficiency in Active Mode of Operation
0.09 × ln (P
115 VAC
78.5
78.8
77.6
75
78
Efficiency (%)
O
71.3
) + 0.49 [ln = natural log]
0.49 × P
0.84 W
230 VAC
74.5
78.8
78.5
79.1
77.7
O
Page 20 of 37

Related parts for RDK-91