POEPHYTEREV-E National Semiconductor, POEPHYTEREV-E Datasheet - Page 61

no-image

POEPHYTEREV-E

Manufacturer Part Number
POEPHYTEREV-E
Description
BOARD EVAL LM5072, DP83848I
Manufacturer
National Semiconductor
Series
PHYTER®r

Specifications of POEPHYTEREV-E

Main Purpose
Special Purpose DC/DC, Power Over Ethernet
Outputs And Type
1, Isolated
Power - Output
24W
Voltage - Output
3.3V
Current - Output
7.3A
Voltage - Input
39 ~ 57V
Regulator Topology
Flyback
Frequency - Switching
250kHz
Board Type
Fully Populated
Utilized Ic / Part
DP83848, LM5072
Lead Free Status / RoHS Status
Not applicable / Not applicable
7.2.12 Energy Detect Control (EDCR)
Bit
7:4
3:0
15
14
13
12
11
10
9
8
ED_DATA_COUNT
ED_AUTO_DOWN
ED_ERR_COUNT
ED_PWR_STATE
ED_BURST_DIS
ED_DATA_MET
ED_ERR_MET
ED_AUTO_UP
Bit Name
ED_MAN
ED_EN
Table 32. Energy Detect Control (EDCR), address 0x1D
0, RO/COR
0, RO/COR
0, RW/SC
0001, RW
0001, RW
Default
0, RW
1, RW
1, RW
0, RW
0, RO
Energy Detect Enable:
Allow Energy Detect Mode.
When Energy Detect is enabled and Auto-Negotiation is disabled
via the BMCR register, Auto-MDIX should be disabled via the PHY-
CR register.
Energy Detect Automatic Power Up:
Automatically begin power up sequence when Energy Detect Data
Threshold value (EDCR[3:0]) is reached. Alternatively, device
could be powered up manually using the ED_MAN bit (ECDR[12]).
Energy Detect Automatic Power Down:
Automatically begin power down sequence when no energy is de-
tected. Alternatively, device could be powered down using the
ED_MAN bit (EDCR[12]).
Energy Detect Manual Power Up/Down:
Begin power up/down sequence when this bit is asserted. When
set, the Energy Detect algorithm will initiate a change of Energy De-
tect state regardless of threshold (error or data) and timer values.
In managed applications, this bit can be set after clearing the Ener-
gy Detect interrupt to control the timing of changing the power
state.
Energy Detect Bust Disable:
Disable bursting of energy detect data pulses. By default, Energy
Detect (ED) transmits a burst of 4 ED data pulses each time the CD
is powered up. When bursting is disabled, only a single ED data
pulse will be send each time the CD is powered up.
Energy Detect Power State:
Indicates current Energy Detect Power state. When set, Energy
Detect is in the powered up state. When cleared, Energy Detect is
in the powered down state. This bit is invalid when Energy Detect
is not enabled.
Energy Detect Error Threshold Met:
No action is automatically taken upon receipt of error events. This
bit is informational only and would be cleared on a read.
Energy Detect Data Threshold Met:
The number of data events that occurred met or surpassed the En-
ergy Detect Data Threshold. This bit is cleared on a read.
Energy Detect Error Threshold:
Threshold to determine the number of energy detect error events
that should cause the device to take action. Intended to allow aver-
aging of noise that may be on the line. Counter will reset after ap-
proximately 2 seconds without any energy detect data events.
Energy Detect Data Threshold:
Threshold to determine the number of energy detect events that
should cause the device to take actions. Intended to allow averag-
ing of noise that may be on the line. Counter will reset after approx-
imately 2 seconds without any energy detect data events.
61
Description
www.national.com

Related parts for POEPHYTEREV-E