Specifications of STEVAL-MKI013V1

Design Resources
STEVAL-MKI013V1 Gerber Files LIS302DL Adapter to DIL24 Schematic LIS302DL Adapter to DIL24 Bill of Materials
Sensor Type
Accelerometer, 3 Axis
Sensing Range
±2.3g, 9.2g
Interface
I²C, SPI
Sensitivity
18 ~ 72 mg/Digit
Voltage - Supply
2.16 V ~ 3.6 V
Embedded
No
Utilized Ic / Part
LIS302DL
Sensing Axis
Triple Axis
Output Type
Digital
Tool / Board Applications
Sensing - Navigation, Accelerometer, Magnetic Field
Mcu Supported Families
LIS302DL
Supported Devices
LIS302DL
Rohs Compliant
Yes
Development Tool Type
Hardware - Daughter Card
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-6342

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STEVAL-MKI013V1
Manufacturer:
STMicroelectronics
Quantity:
135
Part Number:
STEVAL-MKI013V1
Manufacturer:
STMicroelectronics
Quantity:
1
UM0701
7.6.2
Chip selection
Depending on the type of architecture, the user has to select either an analog or digital
MEMS device. After, depending on the precision needed, the user will choose either the
LIS344ALH or LIS3LV02DL, if small-angle detection is required. If such a level of precision
is not needed, one can use the LIS302SG or LIS302DL. If the z axis is not affected (the
device is supposed to tilt around the z axis), a 2-axis accelerometer could be used.
Example 1
In the case of the LIS3LV02DL, the resolution is 1 mg per lsb. Thus, for an acceleration
variation of 1 mg, the angle measured on the z axis will be cos
axis, the angle detection will be sin
measurable is therefore 0.057°. This difference between the x and z axis is explained by the
behavior of the sine/cosine function.
Example 2
In the case of the LIS344ALH, the resolution is given by the formula [noise
density*rt(BW*correction factor)]. BW is the bandwidth and the correction factor is linked to
the low-pass filtering for the V
variation of 0.625 mg, the angle detection on the z axis will be cos
the x axis, the angle detection will be sin
Example 3
In the case of the LIS302DL, the resolution is 18 mg per lsb. Thus, for an acceleration
variation of 18 mg, the angle measured on the z axis will be cos
axis, the angle detection will be sin
Example 4
For the LIS302SG the resolution is 2.5 mg. Thus, the smallest angle variation measurable is
0.14°.
Due to the behavior of the sine/cosine functions and the angle and precision expected, the
user will have to consider the measured acceleration on one or all axes.
OUT
Doc ID 15703 Rev 1
. The resolution is 0.625 mg. Thus, for an acceleration
–1
–1
(10
(18
–3
–3
–1
) = 0.057°. The smallest angle variation
) = 1°.
(0.625*10
–3
) = 0.036°.
STM32-MEMS development kit
–1
–1
(1–10
(1-18
–1
(1-0.625*10
–3
–3
) = 2.5°. For the x
) = 10.9°. For the x
–3
) = 2°. For
37/42