STEVAL-MKI006V1 STMicroelectronics, STEVAL-MKI006V1 Datasheet - Page 30

BOARD EVALUATION LIS302DL

STEVAL-MKI006V1

Manufacturer Part Number
STEVAL-MKI006V1
Description
BOARD EVALUATION LIS302DL
Manufacturer
STMicroelectronics
Series
MEMSr

Specifications of STEVAL-MKI006V1

Design Resources
STEVAL-MKI006V1 Gerber Files STEVAL-MKI006V1 Schematic STEVAL-MKI006V1 Bill of Materials
Sensor Type
Accelerometer, 3 Axis
Sensing Range
±2.3g, 9.2g
Interface
SPI, USB
Sensitivity
18 ~ 72 mg/Digit
Voltage - Supply
5V, USB
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
LIS302DL
Acceleration
2 g, 8 g
Sensing Axis
Triple Axis
Output Type
Digital
Interface Type
USB
Silicon Manufacturer
ST Micro
Silicon Core Number
LIS302DL
Kit Application Type
Sensing - Motion / Vibration / Shock
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-6229

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STEVAL-MKI006V1
Manufacturer:
STMicroelectronics
Quantity:
135
Register description
7.9
7.10
30/42
OUT_Z (2Dh)
Table 30.
Z axis output data.
FF_WU_CFG_1 (30h)
Table 31.
Table 32.
AOI
LIR
ZHIE
ZLIE
YHIE
YLIE
XHIE
XLIE
ZD7
AOI
OUT_Z (2Dh) register
FF_WW_CFG_1 (30h) register
FF_WW_CFG_1(30h) register description
And/or combination of Interrupt events. Default value: 0
(0: OR combination of interrupt events; 1: AND combination of interrupt events)
Latch Interrupt request into FF_WU_SRC reg with the FF_WU_SRC reg cleared by
reading FF_WU_SRC_1 reg. Default value: 0
(0: interrupt request not latched; 1: interrupt request latched)
Enable interrupt generation on Z high event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value higher than preset threshold)
Enable interrupt generation on Z low event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value lower than preset threshold)
Enable interrupt generation on Y high event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value higher than preset threshold)
Enable interrupt generation on Y low event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value lower than preset threshold)
Enable interrupt generation on X high event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value higher than preset threshold)
Enable interrupt generation on X low event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value lower than preset threshold)
ZD6
LIR
ZHIE
ZD5
ZLIE
ZD4
YHIE
ZD3
YLIE
ZD2
XHIE
ZD1
LIS302DL
XLIE
ZD0

Related parts for STEVAL-MKI006V1