IRSLIDER2EK Silicon Laboratories Inc, IRSLIDER2EK Datasheet - Page 8

BOARD EVAL IR SLIDER SI1142

IRSLIDER2EK

Manufacturer Part Number
IRSLIDER2EK
Description
BOARD EVAL IR SLIDER SI1142
Manufacturer
Silicon Laboratories Inc
Series
QuickSense™r
Datasheets

Specifications of IRSLIDER2EK

Sensor Type
Proximity, Infrared
Sensing Range
1 Slider
Interface
USB
Voltage - Supply
5V, USB
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
C8051F800, Si1142
Data Bus Width
8 bit
Interface Type
USB
Operating Voltage
5 V
For Use With/related Products
Si1142
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Sensitivity
-
Lead Free Status / Rohs Status
No
Other names
336-1972
Si1142 Infrared Slider Demo Kit
8
Name
G10
G12
G13
G14
G15
G16
G11
G0
G1
G2
G3
G4
G5
G6
G7
G8
G9
X(mm)
Y(mm)
iLED1
iLED2
PS1bl
PS2bl
Label
PS st
Rad1
Rad2
VIS s
IR st
PS1
PS2
N/A
N/A
VIS
IR
Linearized Distance Measurements
Estimated Location Coordinates
LED Drive Current Levels
AutoRanging Ambient Outputs
AutoRanging PS Outputs
State of Ambient Visible System
State of Ambient IR System
State of PS System
PS Baseline Levels
Unused
Type
Table 1. Generic Data Channels
Rev. 0.2
Using characterization of the PS measurements with
objects at certain distances, it is possible to estimate the
distance of an object based on the PS measurement
value. These three channels represent the distance esti-
mations for each LED's measurement.
With the approximate distance measurements above, an
estimation of X and Y position can be made. These esti-
mations are given in units of mm.
Each LED driver has a specific LED drive current setting
for it. These values are given in units of mA.
AutoRanging will automatically change the modes of the
photodiodes to avoid saturation. When changing modes,
the raw data output changes levels, but AutoRanging will
scale the raw data so that all measurements are on the
same scale. The output from this channel is the pro-
These channels are the AutoRanging PS output from
the device. Raw data measurements are processed by
the AutoRanging firmware to make all the readings
across different modes have the same magnitude. Since
the device switches modes to compensate for ambient
in during each of their respective measurements. The
four possible modes are as follows, Low Light, High
Sensitivity, High Signal, and Sunlight. These modes are
numbered from zero to three. For more information
about each mode, please consult the data sheet.
AutoRanging uses baselining to determine the no-detect
threshold for readings. Any readings below the values
shown on these channels will be considered no-detect
readings. Any values higher than this baseline will be
shown in the AutoRanging PS Outputs above.
The unused channels are not in use by software, but
they are available in firmware to use as needed.
These channels help indicate what mode the sensor is
Description