AS5163 AB austriamicrosystems, AS5163 AB Datasheet - Page 10

no-image

AS5163 AB

Manufacturer Part Number
AS5163 AB
Description
BOARD ADAPTER AS5163
Manufacturer
austriamicrosystems
Datasheets

Specifications of AS5163 AB

Sensor Type
Magnetic, Rotary Position
Sensing Range
360°
Interface
Serial
Voltage - Supply
5V
Embedded
No
Utilized Ic / Part
AS5163
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Sensitivity
-
AS5163
Datasheet - D e t a i l e d D e s c r i p t i o n
7.2.3 Application Specific Programming of the Break Point
The break point BP can be programmed as well with a resolution of 14 bits. This is important when the default transition point is inside the
application range. In such a case, the default transition point must be shifted out of the application range. The parameter BP defines the new
position. The function can be used also for an on-off indication.
Figure 6. Individual Programming of the Break Point BP
7.2.4 Full Scale Mode
The AS5163 can be programmed as well in the full scale mode. The BP parameter defines the position of the transition.
Figure 7. Full Scale Mode
For simplification,
feasible due to saturation effects of the output stage transistors. The actual curve will be rounded towards the supply rails (as indicated
www.austriamicrosystems.com/AS5163
180 degree
BP
Figure 7
CLH
describes a linear output voltage from rail to rail (0V to VDD) over the complete rotation range. In practice, this is not
90 degree
270 degree
100 % VDD
T2
CLL
Application range
0
T1
0 degree
100%VDD
Revision 2.7
CLH
CLL
T2Y
T1Y
0
clamping range
low
mechanical range
electrical range
T1
360
T2
clamping range
high
clamping range
low
Figure
10 - 36
7).

Related parts for AS5163 AB