AG001-01 NVE, AG001-01 Datasheet - Page 115

no-image

AG001-01

Manufacturer Part Number
AG001-01
Description
KIT ENGINEERING EVALUATION
Manufacturer
NVE
Datasheets

Specifications of AG001-01

Rohs Status
RoHS non-compliant
Sensor Type
Magnetic. GMR (Giant Magnetoresistive)
Interface
Analog
Embedded
No
Utilized Ic / Part
AA & AB Series Analog Sensors
Voltage - Supply
-
Sensitivity
-
Sensing Range
-
Other names
391-1003
Application Circuits
Signal processing circuitry for analog output sensors, such as NVE’s ABL-Series products, varies
widely in cost, complexity, and capability. Depending on user requirements, a single op amp design
may be sufficient. For low signal level detection, a low noise instrumentation amp may be desirable.
For complete control of all parameters, use of a complete signal processing IC which can tailor gain,
offset calibration, and temperature compensation may be required. Please see NVE’s Engineering and
Application Notes bulletin for further details on the various approaches that are available.
For digital output applications, NVE’s AKL-Series and DD-Series products provide the most cost
effective approach. Both of these products provide two-wire, i.e., current modulated output signals. For
many applications, an open collector or digital voltage output signal is desirable. The following two
circuits convert a two-wire current modulated signal into an open collector or digital voltage output
signal:
A KL00x Sensor
or DD001 IC
A KL00x
S or DD001 IC
www.nve.com
Ground
Ground
VCC
VCC
100 Ohm
100 Ohm
phone: 952-829-9217 fax: 952-829-9189
VCC
+
VCC
- 115 -
-
+
-
Vref (0.7V)
Comparato r
Open Collector
(Current Sink)
Output
Application Notes
Voltage
Output
Digital

Related parts for AG001-01