Configuring the IP Address from the Command-Line Interface
Connectware Manager
Testing the IP Address Configuration
The set network command is used to configure an IP address from the command line. To
configure the Digi Connect SP through the command line, the DIP switches must be
changed. See "Command Line Access" on page 66 for an illustration of the DIP switch
settings. On the set network command, include the following parameters:
For example:
The IP address cannot be set in Connectware Manager but it can be changed.
Open the browser based on the IP address the device has and go to Configuration >
Network > IP Settings and enter the new IP address, subnet mask, and gateway.
Once the IP address is assigned, you should test the IP address configuration to be sure it
works as configured.
Prerequisite
This procedure assumes that you have configured the device server with an IP address.
Procedure
1
2
ip=device ip: The IP address for the device.
gateway=gateway: The network gateway IP address.
submask=device submask: The device submask.
dhcp=off: Turns off use of the Dynamic Host Configuration Protocol (DHCP),
so that the IP address assigned is permanent.
static=on: Specifies that the IP address is static, and will remain as the specified
IP address, gateway, and submask.
Access the command line of a PC or other networked device.
Issue the following command:
set network ip=10.0.0.1 gateway=255.255.255.0
submask=255.255.255.0 dhcp=off static=on
C o n f i g u r i n g t h e D i g i C o n n e c t D e v i c e s
7 1