SUPERPRO9000U(ROHS) Xeltek, SUPERPRO9000U(ROHS) Datasheet - Page 27

no-image

SUPERPRO9000U(ROHS)

Manufacturer Part Number
SUPERPRO9000U(ROHS)
Description
PROGRAMMER GANG QUAD SKT W/USB
Manufacturer
Xeltek
Series
SuperPro 9000Ur
Type
Gang-Universal Programmerr

Specifications of SUPERPRO9000U(ROHS)

Contents
4 sets 48-DIP Programming Sockets, Programmer, AC Adapter, USB Cable, Users Guide and Power Supply
For Use With/related Products
E/EPROM, FLASH, PLD, Micros and more listed on Device Sheet, 38,000+ Devices Supported.
For Use With
415-1029 - SOCKET ADAPTER FOR SDIP42415-1028 - SOCKET ADAPTER FOR TQFP32415-1027 - SOCKET ADAPTER FOR TSOP56415-1025 - SOCKET ADAPTER FOR SOIC20415-1024 - SOCKET ADAPTER FOR TSOP40415-1023 - SOCKET ADAPTER FOR SOP44415-1022 - SOCKET ADAPTER FOR TSOP56415-1019 - SOCKET ADAPTER FOR SOIC16/SOIC8415-1018 - SOCKET ADAPTER FOR SOIC28415-1015 - SOCKET ADAPTER FOR PLCC28415-1014 - SOCKET ADAPTER FOR PLCC20415-1013 - SOCKET ADAPTER FOR PLCC32415-1017 - SOCKET ADAPTER FOR PLCC44
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
415-1009
SUPERPRO 9000U
SUPERPRO 9000U(ROHS)
4.7 Status Bar
This bar displays the menu info, the process of operation, and a Cancel button.
Click Cancel button, the box will pop up
Cancel process. Continue?
The Cancel operation may destroy the chip, please use it selectively.
5 Trouble Shooting
During the operation, user is able to monitor and correct the progress of the operation through Operation Info
window and message window. This chapter will help user to deal with some common trouble.
5.1 Data File Format
Detail usage of the file type dialogue box.
5.1.1 Intel Hex, Motorola and Tektronix formats
The data for program usually are stored in the data file. Commonly used formats are Intel Hex, Motorola and
Tektronix.
These file formats save data in text mode, which include data info and address info. The offset address is not always
zero. If user loads the file directly, some errors may occur such as the location of data in buffer is incorrect or unable
to load file. The message window is as following:
Invalid file type, or all file data overflow
Resolution:
1) Confirm the file type and ensure the buffer able to load all the file
2) Find the file ’s o ffset address. User can do this by selecting the option to show the start ing address of the file.
File Offset Address (min): 0x0000E0000 (Hex)
This means the offset address of the file is not 0; users need to move the data o f the address to the address 0. To do
that, user should reload the file and enter E000 in the file start address edit line in the File Type dialogue box.
5.1.2 Program a split File to Two or More Chips
By the File Load Mode in the File Type dialogue box, users can program a file data to several chips of the same type.
The how-to is as following:
1. Based on byte (8bit), divide the file into two parts by the odd and even address, and program the two parts into
2. Based on byte (8bit), take a byte within every four bytes, and program the file to four chips. User selects one
Thus the starting address of file will be disp layed after file selection. For example:
two chips respectively. User selects odd in the File Load Mode, the data in the address 0,2,4,6…. will be
programmed to one chip; user selects even, the data in the address 1.3.5.7…. will be programmed to the other
chip.
byte within every four bytes in the File Load Mode box, the data in address 0,4,8,12…. will be programmed to
one chip, others by analogy.