SW500010 Microchip Technology, SW500010 Datasheet - Page 466

HI-TECH C PRO FOR PIC10/12/16

SW500010

Manufacturer Part Number
SW500010
Description
HI-TECH C PRO FOR PIC10/12/16
Manufacturer
Microchip Technology
Type
Compilerr
Series
PIC10/12/16r
Datasheets

Specifications of SW500010

Supported Families
PIC10, PIC12, PIC16
Core Architecture
PIC
Software Edition
Professional
Kit Contents
Software And Docs
Mcu Supported Families
PIC10/12/16
Tool Type
Compiler
Lead Free Status / RoHS Status
Not applicable / Not applicable
For Use With/related Products
PIC10, PIC12, PIC14, PIC16, PIC16E
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
019P
778-1006
778-1006
(1201) all FIND/REPLACE code specifications must be of equal width
All find, replace and mask attributes in this option must be of the same byte width. Check the
parameters supplied to this option. For example finding 1234h (2 bytes) masked with FFh (1 byte)
will result in an error, but masking with 00FFh (2 bytes) will be Ok.
(1202) unknown format requested in -FORMAT: *
An unknown or unsupported INHX format has been requested. Refer to documentation for supported
INHX formats.
(1203) unpaired nibble in * value will be truncated
Data to this option was not entered as whole bytes. Perhaps the data was incomplete or a leading
zero was omitted. For example the value Fh contains only four bits of significant data and is not a
whole byte. The value 0Fh contains eight bits of significant data and is a whole byte.
(1204) * value must be between 1 and * bytes long
An illegal length of data was given to this option. The value provided to this option exceeds the
maximum or minimum bounds required by this option.
(1205) using the configuration file *; you may override this with the environment variable
HTC_XML
This is the compiler configuration file selected during compiler setup. This can be changed via
the HTC_XML environment variable. This file is used to determine where the compiler has been
installed.
(1207) some of the command line options you are using are now obsolete
Some of the command line options passed to the driver have now been discontinued in this version
of the compiler, however during a grace period these old options will still be processed by the driver.
(1208) use –help option or refer to the user manual for option details
An obsolete option was detected. Use –help or refer to the manual to find a replacement option that
will not result in this advisory message.
466
Error and Warning Messages
(Hexmate)
(Hexmate)
(Hexmate)
(Hexmate)
(Driver)
(Driver)
(Driver)

Related parts for SW500010