PROGRAMMER UNIV STANDALONE W/USB

SUPERPRO 5000

Manufacturer Part Number
SUPERPRO 5000
Description
PROGRAMMER UNIV STANDALONE W/USB
Manufacturer
Xeltek
Series
SuperPro 5000r
Type
Universal, Stand Aloner
Datasheet

Specifications of SUPERPRO 5000

Contents
Programmer, Power Supply Adapter, Software, Cables and Documentation
Ic Product Type
Programmer, Universal
Ic Interface Type
USB
No. Of Devices Supported
41848
Kit Contents
Programmer W/ A DIP48 Adapter, AC Adapter, Software CD, USB2.0 Cable, And User's Manual
Rohs Compliant
Yes
For Use With/related Products
E/EPROM, FLASH, PLD, Micros and more listed on Device Sheet. 44,000+ Devices Supported.
For Use With
415-1037 - SOCKET ADAPTER 32PLCC SUPERPRO5K415-1045 - SOCKET ADAPTER 84PLCC SUPERPRO5K415-1044 - SOCKET ADAPTER 28SOIC SUPERPRO5K415-1043 - SOCKET ADAPTER 28SSOP SUPERPRO5K415-1042 - SOCKET ADAPTER 56TSOP SUPERPRO5K415-1041 - SOCKET ADAPTER 40TSOP SUPERPRO5K415-1040 - SOCKET ADAPTER 16SOP SUPERPRO5K415-1039 - SOCKET ADAPTER 48TSOP SUPERPRO5K415-1038 - SOCKET ADAPTER 44PLCC SUPERPRO5K
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
415-1036
‚Library size larger than capacity of CF card‛: The added project needs a larger
storage capacity. Please increase the storage capacity (CF card capacity).
‚Download library OK‛: The library has been downloaded into the programmer
hardware successfully and now the programmer can be used in the standalone
mode.
‚Download library error‛: The library has failed to download into the
programmer hardware. Check whether the CF card is normal.
Making a Chip Blank
For the chip that can be erased electrically, execute the Erase operation.
For the chip that can be erased with ultraviolet ray, use the ultraviolet ray eraser
for 3‐30 minutes.
OTP cannot be blanked once written.
Identifying the Sector
You must identify the Sector to protect some chips.
There are two ways to select the Sector:
Superpro
1. Enter the address of several sectors (maximum of 8) to decide the sectors to
protect. After the Protect operation is performed, the identified sectors are
protected.
®
5000 User’s Guide
77