Y92F-30 Omron, Y92F-30 Datasheet - Page 5

ADAPTER PANEL MNT FOR H3CR/H5CX

Y92F-30

Manufacturer Part Number
Y92F-30
Description
ADAPTER PANEL MNT FOR H3CR/H5CX
Manufacturer
Omron
Type
Panel Mounting Adaptersr
Datasheets

Specifications of Y92F-30

Accessory Type
Panel Mount Adapter, Frame
Mounting Type
Panel Mount
Rohs Compliant
Yes
Length
58 mm
Mounting Hole Size
45 mm
For Use With/related Products
Multiple Series
For Use With
Z3000 - RELAY TIMER DGTL SPDT 12-24VDCZ2999 - RELAY TIMER DGTL SPDT 100/240VACZ2998 - RELAY TIMER DGTL SPDT 100/240VACH3CR-A8E AC100-240/DC100-125 - RELAY ANALOG SET DPDT 8PINZ2815 - RELAY REPEAT CYCLE ANALOG 30HRSZ2387 - RELAY TIMER 0-12SEC OFF-DELAYZ2386 - RELAY TIMER 0-12MIN OFF-DELAYZ2385 - RELAY REPEAT CYCLE ANALOG 30HRSZ2384 - RELAY REPEAT CYCLE ANALOG 300HRSZ2381 - RELAY ANALOG SET DPDT 8PINZ2380 - RELAY ANALOG SET DPDT 8PINZ2379 - RELAY ANALOG SET DPDT 8PINZ2366 - RELAY REPEAT CYCLE ANLG 30HRSZ2382 - RELAY REPEAT CYCLE ANLG 30HRSZ997 - RELAY TIMER ANALOG 24VDC/ACZ2358 - RELAY REPEAT CYCLE ANLG 30HRSZ876 - RELAY TIMER DPDT ANALOG 120\240V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Color
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Y92F30
Z885
H5CR
1 2 3
1 2 3
1 2 3
1 2 3
Timing
diagram
Timing
diagram
Timing
diagram
Timing
diagram
One-shot
Output
Sustained
Output
Output mode B: Repeat cycle 1 (Timer resets when power comes ON.)
One-shot
Output mode B-1: Repeat cycle 2 (Timer does not reset when power comes ON.)
Output
Sustained
Output
One-shot
Sustained output
DOWN
DOWN
DOWN
DOWN
UP
UP
UP
UP
Control output
Control output
Control output
Control output
Start signal
Start signal
Start signal
Start signal
Set value
Set value
Set value
Set value
Set value
Set value
Set value
Set value
Power
Power
Power
Power
Reset
Reset
Reset
Reset
Gate
Gate
Gate
Gate
0
0
0
0
0
0
0
0
One-shot outputs can be set to 0.1 s, 0.5 s, 1 s, 5 s, 10 s, 20 s.
5
** Start signal input is disabled during timing.
** Start signal input is disabled during timing.
** Start signal input is disabled during timing.
The status of the control output is reversed when time
is up (OFF at start).
Start signal
input
** Start signal input is disabled during timing.
Start signal
input
Timing starts when the start signal goes ON.
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Start signal
input
Start signal
input
Timing starts when the start signal goes ON.
The status of the control output is reversed when time
is up (OFF at start).
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
* Normal output operation will not be possible if the
Timing starts when the start signal goes ON.
The control output comes ON when time is up.
While the start signal is ON, the timer starts when
power comes ON or when the reset input goes OFF.
* Normal output operation will not be possible if the
Timing starts when the start signal goes ON.
The control output is turned ON when time is up.
* Normal output operation will not be possible if the
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
* Normal output operation will not be possible if the
Basic Operation
Basic Operation
Basic Operation
Set the value to at least 100 ms (contact output
set time is too short.
type).
set time is too short.
Set the value to at least 100 ms (contact output
Set the value to at least 100 ms (contact output
Set the value to at least 100 ms (contact output
type).
set time is too short.
type).
set time is too short.
type).
Basic Operation
Output
Output
Output
Power
Output
Power
Power
Power
**
**
**
**
Timing
Timing
Timing
Timing
Timing
Sustained
Sustained
Sustained
Timing
Timing
Timing
Timing
Timing
Timing
Timing
H5CR
Timing
Timing

Related parts for Y92F-30