Y92S-38 Omron, Y92S-38 Datasheet - Page 29

LOCK KEY PEN FOR H3DS RELAYS

Y92S-38

Manufacturer Part Number
Y92S-38
Description
LOCK KEY PEN FOR H3DS RELAYS
Manufacturer
Omron
Series
H3DSr
Datasheets

Specifications of Y92S-38

Accessory Type
Tool - Lock Key Pen
For Use With/related Products
H3DS Series
For Use With
H3DS-SLCAC24-230/DC24 - TIMER CAGE CLAMP 17.5MM 4MODESH3DS-MLCAC24-230/DC24-48 - TIMER CAGE CLAMP 17.5MM 8MODESZ2395 - RELAY TIME DELAY 4MODE DIN MNTZ2394 - RELAY TIME DELAY 1MODE DIN MNTZ2393 - RELAY TIME DELAY 8MODE DIN MNTZ2392 - RELAY TIME DELAY 1MODE DIN MNT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Color
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Y92S38
Z2396
■ Characteristics
Connections
■ Block Diagram
■ I/O Functions
Accuracy of operating time ±1% max. of FS (±1% ±10 ms max. at 1.2-s range)
Setting error
Reset time
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
EMC
Case color
Degree of protection
Weight
Inputs
Outputs
http://www.ia.omron.com/
Control output
AC (DC)
input
±10% ± 50 ms max. of FS
0.1 s max.
±0.5% max. of FS (±0.5%±10 ms max. at 1.2-s range)
±5% max. of FS (±5%±10 ms max. at 1.2-s range)
100 MΩ min. at 500 VDC
Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC for 1 min
3 kV (between power supply terminals)
4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts)
Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) ±1.5 kV (between power
supply terminals)
Malfunction: 4 kV
Destruction: 8 kV
Malfunction: 0.5-mm single amplitude at 10 to 55 Hz
Destruction: 0.75-mm single amplitude at 10 to 55 Hz
Malfunction: 200 m/s
Destruction: 300 m/s
(EMI)
Emission Enclosure:
Emission AC Mains:
Harmonic Current:
Voltage Fluctuation and Flickering: EN61000-3-3
(EMS)
Immunity ESD:
Immunity RF-interference from AM Radio Waves:
Immunity Burst:
Immunity Surge:
Light gray (5Y7/1)
IP30 (IP20 for terminal block)
Approx. 70 g
Power supply
circuit
---
Outputs are turned ON when the preset value is reached.
2
2
, 3 times each in 6 directions
, 3 times each in 6 directions
Zero setting
detection
circuit
Oscillation
circuit
EN61812-1
EN55011 Group 1 class B
EN55011 Group 1 class B
EN61000-3-2
EN61812-1
EN61000-4-2: 6 kV contact discharge (level 3)
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
EN61000-4-4: 2 kV power port and output port (level 3)
EN61000-4-5: 2 kV common mode (level 3)
Time scale/
unit selectors
Counting
circuit
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
8 kV air discharge (level 3)
1 kV control port with capacitive clamp (level 3)
1 kV differential mode (level 3)
Indicator
circuit
Output
circuit
H3DS-X
29