G32A-A10-VD DC5-24 Omron, G32A-A10-VD DC5-24 Datasheet

REPLACEMENT POWER CARTRIDGE 10A

G32A-A10-VD DC5-24

Manufacturer Part Number
G32A-A10-VD DC5-24
Description
REPLACEMENT POWER CARTRIDGE 10A
Manufacturer
Omron
Series
G3PAr
Datasheets

Specifications of G32A-A10-VD DC5-24

Accessory Type
Power Device Cartridge
Control Voltage Range
19 VAC to 264 VAC
Load Voltage Rating
264 V
Load Current Rating
10 A
Output Device
Triac
Relay Type
Solid State
Input Type
DC
Output Type
AC
Input Voltage (max)
30V
Output Voltage (max)
264V
Input Current (max)
7mA
Output Current
10A
Isolation Voltage
4kV
Mounting
Din-Rail
Operating Temp Range
-30C to 80C
Operating Temperature Classification
Commercial
Rad Hardened
No
For Use With/related Products
G3PA Series
For Use With
G3PA-210B-VDDC5-24 - RELAY SSR SPST 10A 24VDC DIN MT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Color
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G32A-A10-VDDC5-24
G32AA10VDDC524
G32AA10VDDC524NC
Single Phase SSRs with Built-in Heat
Sinks
• Built-in heat sink increases service life and reliability for fre-
• Operation indicator turns on when control power is applied
• DIN rail mount
• Relays with replaceable triac output cartridge (G3PA) sim-
• Built-in linking brackets for dense side-by-side mounting
• Conforms to international safety standards: UL508 File
Specifications
• Zero cross function, reduces initial inrush load currents
• Leakage current:
■ G3PA Single-Phase SSRs, Replaceable Triac Output Cartridge
100 x 27 x 100
100 x 37 x 100
100 x 47 x 100
quently cycling circuits
plifies maintenance
(G3PA)
No. E64562; CSA C22.2 (No. 14, No. 950) File No.
LR35535; EN60950 File No. 5915UG
Solid State Relays
G3PA/G3PB
• 10 A and 20 A G3PA: 5 mA max. at 120 VAC 10 mA max. at 230
H x W x D mm
Appearance/
Dimensions
VAC
Phototriac
Phototriac
Phototriac
Isolation
5-24 VDC
5-24 VDC
5-24 VDC
Input voltage
10 amps
20 amps
40 amps
Load current
19 to 264 VAC
(50/60 Hz)
19 to 264 VAC
(50/60 Hz)
19 to 264 VAC
(50/60 Hz)
Load voltage
• 40 A and 60 A G3PA: 10 mA max. at 120 VAC 20 mA max. at
• 20 A, 200-480 VAC G3PA: 20 mA max. at 400 VAC
• All G3PB models: 10 mA max. at 200 VAC
230 VAC
Solid State Relays
150 amps, 60 Hz
220 amps, 60 Hz
440 amps, 60 Hz
Inrush current
G3PA/G3PB
G3PA-210B-VD DC5-24
G3PA-220B-VD-DC5-24
G3PA-240B-VD-DC5-24
Model
1

Related parts for G32A-A10-VD DC5-24

G32A-A10-VD DC5-24 Summary of contents

Page 1

... Built-in heat sink increases service life and reliability for fre- quently cycling circuits • Operation indicator turns on when control power is applied • DIN rail mount • Relays with replaceable triac output cartridge (G3PA) sim- plifies maintenance • Built-in linking brackets for dense side-by-side mounting (G3PA) • ...

Page 2

... G3PA-220-VD DC5-24 G3PA-240-VD DC5-24 G3PA-260-VD DC5-24 G3PA-420-VD DC12-24 Inrush current Model G3PA-260B-VD DC5-24 G3PA-420B-VD DC5-24 Inrush current Model G3PB-215B-VD DC12-24 G3PB-225B-VD DC12-24 G3PB-235B-VD DC12-24 G3PB-245B-VD DC12-24 Model PFP-50N PFP-100N PFP-100N2 PFP-M Model G32A-A10-VD DC5-24 G32A-A20-VD DC5-24 G32A-A40-VD DC5-24 G32A-A60-VD DC5-24 G32A-A420-VD DC12-24 ...

Page 3

... III. PRECAUTIONS 1. Suitability THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE BUYER’S APPLICATION INCLUDING (A) ELECTRICAL OR ELECTRONIC COMPONENTS, (B) CIRCUITS, (C) SYSTEM ASSEMBLIES, (D) END PRODUCT, (E) SYSTEM, (F) MATERIALS OR SUBSTANCES OR (G) OPERATING ENVIRONMENT ...

Page 4

... THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section. ...

Related keywords