HK2 Crydom Co., HK2 Datasheet - Page 15

KIT BRACKT HARDWARE DIN RAIL MNT

HK2

Manufacturer Part Number
HK2
Description
KIT BRACKT HARDWARE DIN RAIL MNT
Manufacturer
Crydom Co.
Datasheets

Specifications of HK2

Accessory Type
Mounting Hardware
Associated Relay Series
HS351, HS301, HS271, HS201, HS172, HS151, HS122
Mounting Style
Panel
Termination Style
Screw
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
DIN Rail Adapter Kits
For Use With
CC1704 - DIN BRACKET KIT 45MM
Color
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
CC1707

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HK2000A/B
Quantity:
12 800
Part Number:
HK2000C/D
Quantity:
12 800
Part Number:
HK2000E/F
Quantity:
12 800
Part Number:
HK2000G
Quantity:
12 800
Part Number:
HK2000H
Quantity:
12 800
Company:
Part Number:
HK2110NT6TR
Quantity:
15 000
Part Number:
HK212510NJ
Manufacturer:
TAIYO/太诱
Quantity:
20 000
Part Number:
HK212518NJ
Manufacturer:
TAIYO/太诱
Quantity:
20 000
Part Number:
HK212518NJ-T
Manufacturer:
TAIYO/太诱
Quantity:
20 000
Part Number:
HK212518NJ-TV
Manufacturer:
TAIYO/太诱
Quantity:
20 000
Part Number:
HK21251N5S
Manufacturer:
TAIYO/太诱
Quantity:
20 000
HS072-D2490
HS072-HD6090
Derating Curve
2
70
60
50
40
30
20
10
0
For comprehensive mechanical specifications of these and other Crydom products visit
20
1
2
3
4
4
Heat Sink (HS072)
Thermal Pad (TP01)
SSR (See table above for options)
Hardware Kit 1 (HK1)
Included
SSRs
1
1
HS072 w/90 A single channel SSR
30
HS072 Assemblies
Assembly includes
65 Amp AC output @ 40 °C
24 to 280 or 48 to 660 VAC line
voltage range
Single channel output
3 to 32 VDC input control voltage
Panel mounted
UL, CSA, VDE, CE approved SSRs
Ambient Temperature, °C
40
Line
Voltage
Range
Vrms
24-280
48-660
50
Load
Current
Range
Arms
.04-65
.04-65
60
3
Control
Voltage
Range
Vdc
3-32
3-32
70
Control
Current
mA
3.4 @ 5Vdc
2.0 @ 5Vdc
80
1
HS053-D24125
HS053-HD60125
3 Phase
HS053-D53TP50D
*
Derating Curve
Output current specification is total combined load current for all conducting channels.
1
2
3
4
Heat Sink (HS053)
Thermal Pad (TP01/TP03)
SSR (See table above for options)
Hardware Kit 1 (HK1)
Assembly includes
100
80
60
40
20
0
20
HS053 w/125 A single channel
or 50 A/channel 3 Phase
Included
SSRs
1
30
Included
SSRs
1
1
2
Ambient Temperature, °C
HS053 Assemblies
40
82.5 Amp AC output @ 40 °C
24 to 280 or 48 to 660 VAC line
voltage range
Single channel or 3 phase outputs
3 to 32 VDC input control voltage
Panel mounted
UL, CSA, VDE, CE approved SSRs
Line
Voltage
Range
Vrms
48-530
Line
Voltage
Range
Vrms
24-280
48-660
4
50
www.crydom.com
Load
Current
Range*
Arms
.05-82.5
Load
Current
Range
Arms
.15-82.5
.15-82.5
60
SSR*
Control
Voltage
Range
Vdc
3-32
Control
Voltage
Range
Vdc
3-32
3-32
70
80
Control
Current
mA
3.4 @ 5Vdc
2.0 @ 5Vdc
Control
Current
mA
10 @ 5Vdc
3
1
15

Related parts for HK2