G8P-1AP DC5 Omron, G8P-1AP DC5 Datasheet - Page 2

RELAY PC MNT 30A SPST 5V OPEN

G8P-1AP DC5

Manufacturer Part Number
G8P-1AP DC5
Description
RELAY PC MNT 30A SPST 5V OPEN
Manufacturer
Omron
Series
G8Pr
Datasheet

Specifications of G8P-1AP DC5

Relay Type
General Purpose
Contact Form
SPST-NO (1 Form A)
Contact Rating (current)
30A
Switching Voltage
250VAC, 28VDC - Max
Coil Type
Standard
Coil Current
185mA
Coil Voltage
5VDC
Turn On Voltage (max)
3.75 VDC
Turn Off Voltage (min)
0.5 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPST-NO (1 Form A)
Contact Rating @ Voltage
30A @ 250VAC
Control On Voltage (max)
3.75 VDC
Control Off Voltage (min)
0.5 VDC
Coil Voltage Vdc Nom
5V
Contact Current Max
30A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
28V
Coil Resistance
27ohm
Contact Configuration
SPST-NO
Relay Mounting
PCB
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G8P-1A-DC5
G8P-1AP-DC5
G8P1APDC5
Z1002
■ Coil Data
Note: The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with tolerances of ±10%.
■ Characteristics
Note: 1. Data shown are of initial value. Operate and release times excluding bounce.
■ Characteristic Data
226
5
9
12
24
48
110
Contact resistance
Operate time
Release time
Insulation resistance
Dielectric strength
Impulse surge withstand
Vibration
Shock
Ambient temperature
Humidity
Service life
Maximum switching capacity
SPST-NO
voltage
2. Please vent sealed relays after processing in order to achieve rated electrical service life, by removing the vent nib.
Rated
(VDC)
Rated operating voltage (V)
Power PCB Relay
185
93
77
36
19
9
current
Rated
(mA)
Mechanical durability 10 to 55 Hz, 1.65 mm (0.06 in) double amplitude for 2 hours
Malfunction durability 10 to 55 Hz, 1.65 mm (0.06 in) double amplitude for 5 minutes
Mechanical durability 1,000 m/s
Malfunction durability 100 m/s
Mechanical
Electrical
27
97
155
660
2,480
12,400
G8PT
resistance
Coil
(Ω)
75% max.
100 mΩ max. (measured with 5 VDC, 1 A)
15 ms. max.
10 ms. max.
100 MΩ min. (at 500 VDC)
2,500 VAC, 50/60 Hz for 1 minute (coil to contacts),
1,500 VAC, 50/60 Hz for 1 minute (between contacts)
6,000 V between coil to contacts (1.2 μs/50 μs & 100 kHz ring wave per IEC 1000-4-12)
-55° to 105°C, cold coil condition (with no icing)
-55° to 85°C, hot coil condition (hot start) (with no icing)
5% to 85% RH
10 million operations minimum
100,000 operations, 360 ops/hr, at rated load (minimum)
Pick-up
voltage
2
(approx. 10 G)
2
(approx. 100 G)
SPDT
% of rated voltage
10% min.
Dropout
voltage
Rated operating voltage (V)
120% max.
Maximum
voltage
Approx. 900
consumption
Power
(mW)