JW
SPECIFICATIONS
Contact
Coil
#1 This value can change due to the switching frequency, environmental conditions,
Remarks
* Specifications will vary with foreign standards certification ratings.
*
*
*
*
*
*
*
*
1
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Rating
(resistive
load)
Expected
life (min.
ope.)
Nominal operating power
1
2
3
4
5
6
7
8
Detection current: 10mA
Wave is standard shock voltage of 1.2 50s according to JEC-212-1981
Excluding contact bounce time
Half-wave pulse of sine wave: 11ms; detection time: 10s
Half-wave pulse of sine wave: 6ms
Detection time: 10s
Refer to “6. Usage, Storage and Transport Conditions“ in
ENVIRONMENT section in Relay Technical
When using relays in a high ambient temperature, consider the pick-up voltage
rise due to the high temperature (a rise of approx. 0.4% V for each 1°C
with 20°C
maximum allowable voltage range.
and desired reliability level, therefore it is recommended to check this with the
actual load.
68°F
Nominal switching
capacity
Max. switching
power
Max. switching
voltage
Max. switching
current
Min. switching
capacity
Mechanical
(at 180 cpm)
Electrical (at 6 cpm)
(Resistive load)
.1.126
as a reference) and use a coil impressed voltage that is within the
28.6
#1
1 Form A, 1 Form C,
2 Form A, 2 Form C
1,250 VA, 150 W
12.8
.504
Standard type
5 A 250 V AC,
5 A 30 V DC
20.0
.787
mm
5 A
Information.
1c, 2a, 2c: AgNi type
inch
250 V AC, 30 V DC
1a: AgSnO
100 mA, 5 V DC
530 mW
100 m
510
10
FEATURES
• Miniature package with universal
• High dielectric withstanding for
• Sealed construction
• Class B coil insulation types
• TV rated (TV-5) types available
• VDE, TÜV, SEMKO, SEV, FIMKO, TV-5
5
AMBIENT
1 Form A, 1 Form C
terminal footprint
transient protection:
10,000 V surge in μs between coil
and contact
available
(only for 1 Form A type)
also approved
High capacity type
6
2
2,500 VA, 300 W
10 A 250 V AC,
type
10 A 30 V DC
COMPACT PC BOARD
10 A
POWER RELAY
33.8°F
Characteristics
Max. operating speed
(at rated load)
Initial insulation resistance
Initial
breakdown
voltage*
Initial surge voltage between
contacts and coil*
Operate time*
(at nominal voltage)
Release time (without diode)*
(at nominal voltage)
Temperature rise (at 20°C)
(at nominal voltage)
(with nominal coil voltage and
at nominal switching capacity)
Shock
resistance
Vibration
resistance
Conditions for operation,
transport and storage*
(Not freezing and
condensing at low
temperature)
Unit weight
1
Between open
contacts
Between contacts
and coil
Between contact
sets
Functional*
Destructive*
Functional*
Destructive
3
2
7
Ambient
temp.*
Humidity
4
6
5
About Cd-free contacts
We have introduced cadmium-free type
products to reduce environmentally
hazardous substances. Please replace
parts that contain cadmium with Cd-free
products. Evaluate them with your actual
application before use because the life of
a relay depends on the contact material
and load.
Note: Add the suffix “F” to the part
number for the 1 Form A contact type.
The 1 Form C, 2 Form A and 2 Form C
contact types were originally Cd-free,
hence the suffix “F” is not required.
8
JW RELAYS
3
3,000 Vrms for 1 min. (2 Form A, 2 Form C)
1c, 2a, 2c: max. 55C
10 to 55 Hz at double amplitude of 1.6 mm
10 to 55 Hz at double amplitude of 2.0 mm
(resistance method)
Standard type
1a: max. 45C
–40C to +85C
Min. 1,000 M at 500 V DC
VDE
ds_61B08_en_jw: 101008D
Min. 980 m/s
1,000 Vrms for 1 min.
5,000 Vrms for 1 min.
Approx. 13 g
Min. 98 m/s
Min. 10,000 V
5 to 85% R.H.
Max. 15 ms
Max. 5 ms
6 cpm
–40F to +185F
(resistance method)
High capacity type
2
2
{10 G}
{100 G}
.46 oz
1a: max. 45C
1c: max. 55C