RELAY PWR SPST 22A 24VDC 1400MW

ALFG1PF24

Manufacturer Part Number
ALFG1PF24
Description
RELAY PWR SPST 22A 24VDC 1400MW
Manufacturer
Panasonic Electric Works
Series
ALFGr
Datasheets

Specifications of ALFG1PF24

Relay Type
General Purpose
Contact Form
SPST-NO (1 Form A)
Contact Rating (current)
25A
Switching Voltage
250VAC
Coil Type
Standard
Coil Current
58.6mA
Coil Voltage
24VDC
Turn On Voltage (max)
16.8 VDC
Turn Off Voltage (min)
2.4 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPST-NO (1 Form A)
Contact Rating @ Voltage
25A @ 250VAC
Control On Voltage (max)
16.8 VDC
Control Off Voltage (min)
2.4 VDC
Contact Gap
1.5 mm (0.59")
En61810-1 Certified
2.5 kV Surge Breakdown Voltage (Between Contacts)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-2590
ALFG1PF24

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ALFG1PF24
Manufacturer:
PANASONIC/松下
Quantity:
20 000
ORDERING INFORMATION
ds_61B12_en_lfg: 280211D
LF-G relay
Contact arrangement
1: 1 Form A Standard type (22A)
2: 1 Form A High capacity type (31A)
Terminal shape
P: PCB type
Coil insulation class
F: UL Class F
Nominal coil voltage (DC)
09: 9V, 12: 12V, 18: 18V, 24: 24V
Note: UL, C-UL and VDE approved type is standard.
ALFG
P
FEATURES
• High capacity
High capacity control possible at 22A/
31A (High capacity type) 250V AC rating
in compact size (L: 15.7  W: 30.1 
H: 23.3 mm
inch)
• Contact gap: 1.5 mm
Compliant with European photovoltaic
standard (VDE0126).
EN61810-1 certified: 2.5 kV surge
breakdown voltage (between contacts)
• Coil holding voltage contributes to
saving energy of equipment
The coil holding voltage can be reduced
up to 35%V of the nominal coil voltage
(Ambient temperature: 20C 68F).
Power consumption at the lowest coil
holding voltage: 170 mW equivalent
*Coil holding voltage is the coil voltage
after 100 ms from the applied nominal
coil voltage.
*When the ambient temperature during
use is 85C 185F, make the coil holding
voltage between 45% and 80%V of the
nominal coil voltage.
• High insulation resistance
Creepage distance between contact and
coil terminal: Min. 9.5 mm
Clearance distance between contact and
coil terminal: Min. 6.5 mm
Surge breakdown voltage: 6 kV
• Conforms to various safety
standards
UL, C-UL and VDE approved
F
Ideal for Solar inverter
1 Form A 22A/31A
Compact size,
L: .618  W: 1.185  H: .917
Power Relay
.059 inch
.354 inch
.256 inch
TYPICAL APPLICATIONS
• Photovoltaic power generation
systems (Solar inverter)
• Uninterruptible Power Supplies
(UPS)
• Home appliances
• Office equipment
LF-G RELAYS (ALFG)
LF-G (ALFG)
VDE
1

Related parts for ALFG1PF24

ALFG1PF24 Summary of contents

Page 1

... Surge breakdown voltage • Conforms to various safety standards UL, C-UL and VDE approved P F LF-G (ALFG) VDE LF-G RELAYS (ALFG) TYPICAL APPLICATIONS • Photovoltaic power generation systems (Solar inverter) • Uninterruptible Power Supplies (UPS) • Home appliances • Office equipment 1 ...

Page 2

... Humidity 85% R.H. (Not freezing and condensing at low temperature) Air pressure 106 kPa Part No. Standard type High capacity type ALFG1PF09 ALFG2PF09 ALFG1PF12 ALFG2PF12 ALFG1PF18 ALFG2PF18 ALFG1PF24 ALFG2PF24 Coil resistance Nominal operating power 58 103 1,400mW 230 410 Specifications High capacity type 1 Form A Max. 100 m ...

Page 3

REFERENCE DATA  Standard type 1. Coil temperature rise Sample: ALFG1PF09, 6 pcs. Point measured: coil inside Ambient temperature: 20C 68F, 60C 140F Contact carrying current: 22A 100 20°C 68°F 22A 60°C 140°F 22A 80 20°C 68°F 0A 60°C 140°F ...

Page 4

... Ambient temperature, °C Change of pick-up and drop-out voltage Pick-up voltage Drop-out voltage No. of operations, ×10 your local Panasonic Electric Works representative. External dimensions 0.5 .020 12.0 22.0 .472 .866 27.6 1.087 30.1 1.185 Dimension: General tolerance 0.1 .004 Max. 1mm ...

Page 5

NOTES  Usage, transport and storage conditions 1) Temperature: –40 to +60C –40 to +140F (When nominal coil voltage applied) –40 to +85C –40 to +185F (When coil holding voltage is 45% to 80% of the nominal coil voltage) 2) ...