G7J-3A1B-B-W1 AC100/120 Omron, G7J-3A1B-B-W1 AC100/120 Datasheet - Page 3

RELAY PWR 3PST-NO/1NC 25A 120VAC

G7J-3A1B-B-W1 AC100/120

Manufacturer Part Number
G7J-3A1B-B-W1 AC100/120
Description
RELAY PWR 3PST-NO/1NC 25A 120VAC
Manufacturer
Omron
Series
G7Jr
Datasheet

Specifications of G7J-3A1B-B-W1 AC100/120

Relay Type
General Purpose
Contact Form
4PST (3 Form A, 1 Form B)
Contact Rating (current)
25A
Switching Voltage
250VAC, 125VDC - Max
Coil Type
Standard
Coil Current
21.6mA
Coil Voltage
120VAC
Turn On Voltage (max)
75 VAC
Turn Off Voltage (min)
18 VAC
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Circuit
4PST (3 Form A, 1 Form B)
Contact Rating @ Voltage
25A @ 220VAC
Control On Voltage (max)
75 VAC
Control Off Voltage (min)
18 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G7J-3A1-B-B-W1-AC100/120
G7J-3A1-BBW1AC100120
G7J-3A1B-B-W1AC100/120
G7J3A1BBW1AC100120
Z1033
Engineering Data
Motor Load Performance
Ambient Temperature vs. Must-operate
and Must-release Voltage
Load
Endurance
Maximum Switching Power
G7J 100 to 120 VAC
G7J 24 VDC
DC resistive
load (NO
contact)
DC resistive load
(NC contact)
Number of Relays: 5
Number of Relays: 5
Switching voltage (V)
AC resistive load
(cosφ = 1)
AC inductive load
(cosφ = 0.4)
(NO contact)
Item
Ambient temperature (°C)
Ambient temperature (°C)
AC resistive load
(cosφ = 1)
AC inductive load
(cosφ = 0.4)
(NC contact)
300
3φ, 220 VAC, 2.7 kW (with a inrush current of 78 A and a breaking current of 13 A)
Electrical: 100,000 operations min.
Must-operate voltage
Must-release voltage
Must-operate voltage
Must-release voltage
Endurance
5,000
3,000
1,000
700
500
300
100
70
50
G7J-4A-P, G7J-3A1B-P, G7J-4A-B, G7J-3A1B-B, G7J-4A-T, G7J-3A1B-T
220 VAC (NC contact)
220 VAC (NO contact)
Switching current (A)
Ambient Temperature vs. Coil
Temperature Rise
G7J-4A 100 to 120 VAC
G7J-4A 24 VDC
General Purpose Relay
Number of Relays: 5
Number of Relays: 5
Number of samples: 5
Measurement conditions: Increase and decrease the specified shock
gradually imposed in ±X, ±Y, and ±Z directions three times each with
the Relay energized and not energized to check the shock values
that cause the Relay to malfunction.
Criteria: There must not be any contact separation for 1 ms or greater
with a shock of 100 m/s
a shock of 20 m/s
Button upwards
A1 downwards
Malfunctioning Shock
G7J-2A2B
Unit: m/s
Ambient temperature (°C)
Ambient temperature (°C)
2
2
when the coil is not energized.
2
imposed when the coil is energized or with
Terminals
downwards
Terminals upwards
Not energized
G7J
Energized
Button
downwards
A2
downwards
Shock direction
301