G7SA-3A1B-DC24 Omron, G7SA-3A1B-DC24 Datasheet
G7SA-3A1B-DC24
Specifications of G7SA-3A1B-DC24
Z2943
Related parts for G7SA-3A1B-DC24
G7SA-3A1B-DC24 Summary of contents
Page 1
... CSA standard CSA C22.2 No. 14 Industrial Control Devices Must-operate Must-release voltage voltage 75% max. (V) 10% min. (V) Relays with Forcibly Guided Contacts Rated voltage Model 24 VDC G7SA-3A1B G7SA-2A2B G7SA-5A1B G7SA-4A2B G7SA-3A3B Poles Rated voltage Model 4 poles --- P7SA-10F 6 poles P7SA-14F 4 poles 24 VDC P7SA-10F-ND 6 poles ...
Page 2
... C. G-4 Relays with Forcibly Guided Contacts Resistive load 250 VAC VDC 6 A 250 VAC, 125 VDC 6 A Dielectric strength 2,500 VAC for 1 min. between poles max. min. (at 500 VDC Approx Approx G7SA Insulation resistance 1,000 M min. (See note 2.) ...
Page 3
... View) ( 0.1 tolerance) Fourteen, 1.4 dia. Note: 1. Terminals 23-24, 33-34, 53-54, and 63-64 are normally open. Terminals 11-12, 21-22, and 31-32 are normally closed. 2. The colors of the cards inside the Relays are as follows: G7SA-5A1B: Blue, G7SA- 4A2B: White, and G7SA-3A3B: Yellow. ...
Page 4
... View) Two, 4 dia. or M3.5 6 Relays with Forcibly Guided Contacts G7SA-2A2B Mounted This display circuit available only for "-ND" models. Note: Terminals 23-24, 33-34, and 43-44 are normally open. Terminals 11-12 and 21-22 are normally closed. G7SA-4A2B G7SA-3A3B Mounted Mounted ...
Page 5
... Three, 2.6 dia. (for M3 tapping screws) Terminal Arrangement/Internal Connection Diagram (Bottom View) G7SA-5A1B Mounted G7SA-4A2B Mounted G7SA-3A3B Mounted G7SA Mounting Hole Placement (Bottom View) ( 0.1 tolerance) Three, 3.2 dia. (for M3 tapping screws) Ten, 1.1 dia. Note: Terminals 23-24, 33-34, and 43-44 are normally open ...
Page 6
... N·m securely. Wire the terminals correctly with no mistakes in coil polarity, otherwise the G7SA will not operate. Cleaning The G7SA is not of enclosed construction. Therefore, do not wash the G7SA with water or detergent. ■ Forcibly Guided Contacts (from EN50205 contact becomes welded, all NC contacts will maintain a minimum distance of 0 ...
Page 7
... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...
Page 8
Cat. No. GC SAFETY-3A 07/05-11/06 Specifications subject to change without notice Printed in USA ...