SF4D-DC24V Panasonic Electric Works, SF4D-DC24V Datasheet - Page 4

RELAY SAFETY 6A 24VDC PCMNT 8PST

SF4D-DC24V

Manufacturer Part Number
SF4D-DC24V
Description
RELAY SAFETY 6A 24VDC PCMNT 8PST
Manufacturer
Panasonic Electric Works
Series
SFr
Type
Safety Relayr
Datasheets

Specifications of SF4D-DC24V

Relay Type
Safety
Contact Form
8PST (4 Form A, 4 Form B)
Contact Rating (current)
6A
Switching Voltage
250VAC
Coil Type
Standard
Coil Current
20.8mA
Coil Voltage
24VDC
Turn On Voltage (max)
14.4 VDC
Turn Off Voltage (min)
3.6 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
8PST (4 Form A, 4 Form B)
Contact Rating @ Voltage
6A @ 250VAC
Control On Voltage (max)
14.4 VDC
Control Off Voltage (min)
3.6 VDC
Brand/series
SF Series
Current, Rating
6 A
Function
Safety
Material, Contact
Gold-Flashed Silver Alloy
Number Of Pins
18
Resistance, Coil
1.152 Ohms
Standards
cULus, TUV, CSA
Temperature, Operating
-40 to +70 °C
Termination
Solder
Voltage, Breakdown
2500 V (RMS) (Between Contacts and Coil)
Voltage, Control
24 VDC
Voltage, Rating
380 VAC
Weight
1.66 Oz. (Approx.)
Relay Construction
Non-Latching
Contact Arrangement
4PST-NO/4PST-NC
Coil Voltage Dc
24V
Voltage Rating (vdc)
30V
Voltage Rating (vac)
440V
Dropout Volt (min)
3.6VDCV
Coil Resistance
1.152kohm
Pick-up Voltage (max)
18VDC
Maximum Power Rating
180W/1.5KVA
Operate Time
30ms
Contact Current Rating
6A
Contact Material
Silver Tin Oxide/Gold Flash
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Unsealed
Product Height (mm)
16.5mm
Product Depth (mm)
33mm
Product Length (mm)
53.3mm
Operating Temp Range
-40C to 70C
Pin Count
18
Mounting Style
Through Hole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-1441

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
SF4D-DC24V
Quantity:
29
SAFETY STANDARDS
* CSA standard: Certified by C-UL
SAFETY STRUCTURE OF SF RELAYS
This SF relay design ensures that
subsequent operations shut down and
can automatically return to a safe state
when the SF relay suffers overloading
and other circuit abnormalities
E120782*
1. Forced operation method
2. Independent operation method
3. Separate chamber method
4. 2 Form A 2 Form B contact
(2 Form A 2 Form B,
4 Form A 4 Form B types)
(4 Form A 4 Form B type)
(2 Form A 2 Form B,
4 Form A 4 Form B types)
4 Form A 4 Form B contact
File No.
UL/C-UL (Recognized)
6A 250V AC
6A 24V DC
Contact rating
The two contacts “a” and “b” are coupled with the same card. The operation
of each contact is regulated by the movement of the other contact.
None of four contacts are held in position by the armature. Even though one
of the external N.O. contacts has welded, the other three contacts have
returned owing to the de-energizing of the coil.
In independent chambers, the contacts “a” and “b” are kept apart by a body/
case separator or by the card itself.
Structure with independent COM contact of 2 Form A 2 Form B and
4 Form A 4 Form B contacts.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Return
Return
Card
Case separator
968 EZ 116.00 01 (SF2D)
968 EZ 113.00 01 (SF4D)
(unforeseen externally caused circuit or
device breakdowns, end of life incidents,
and noise, surge, and environmental
influences) owing to contact welding,
spring fusion or, in the worst-case
File No.
1
Structure
Weld
TÜV (Certified)
Card
Min. 0.5 mm
8A 24V DC
6A 230V AC
Contact a
Contact b
2
External NO
contact weld
Return
Contact a
Body
separator
Contact b
.020 inch
Rating
01, 1851
Even when one contact is welded closed, the other
maintains a gap of greater than 0.5 mm
In the diagram on the left, the lower contact “b” have
welded but the upper contact “a” maintain at a gap of
greater than 0.5 mm
Subsequent contact movement is suspended and the
weld can be detected
Enables design of safety circuits that allow weld
detection and return at an early stage.
As shown at the top right of the diagram on the left, if
the external N.O. contact welds, a 0.5 mm
gap is maintained.
Each of the other contacts returns to N.O. because
the coil is no longer energized.
Prevents shorting and fusing of springs and spring
failure owing to short-circuit current.
As shown on the diagram on the left, even if the
operating springs numbered 1 and 2 there is no
shorting between “a” and “b” contacts.
Independent COM enables differing pole circuit
configurations. This makes it possible to design
various kinds of control circuits and safety circuits.
SF Double contact type
scenario, relay breakdown (coil rupture,
faulty operation, faulty return, and fatigue
and breakage of the operating spring and
return spring), and even in the event of
end of life.
File No.
.020
Operation
SEV
inch.
6A 230V AC
6A 24V DC
Contact rating
.020
.020 inch
inch.