MY4-02 DC6 Omron, MY4-02 DC6 Datasheet - Page 12

RELAY GP 4PDT 3A 6VDC

MY4-02 DC6

Manufacturer Part Number
MY4-02 DC6
Description
RELAY GP 4PDT 3A 6VDC
Manufacturer
Omron
Series
MYr
Datasheet

Specifications of MY4-02 DC6

Relay Type
General Purpose
Contact Form
4PDT (4 Form C)
Contact Rating (current)
3A
Switching Voltage
250VAC, 125VDC - Max
Coil Type
Standard
Coil Current
150mA
Coil Voltage
6VDC
Turn On Voltage (max)
4.8 VDC
Turn Off Voltage (min)
0.6 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
4PDT (4 Form C)
Contact Rating @ Voltage
3A @ 220VAC
Control On Voltage (max)
4.8 VDC
Control Off Voltage (min)
0.6 VDC
Contact Rating
3 A at 250 VAC, 30 VDC
Contact Termination
Solder Pin
Mounting Style
Snap In
Power Consumption
0.9 W
Coil Resistance
39.8 Ohms
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MY4-02DC6
MY402DC6
12
MY
Unit: mm (inch)
■ ACCESSORIES (continued)
Socket mounting plates [t=1.52 (.06)]
PYP-1
■ RELAY OPTIONS
LED Indicator
Specifications and dimensions same as the standard type
with the following exception. Because an LED indicator is
employed as the operation indicator, the rated current is
approximately 3.8 mA higher in the DC types and 0.5 to 5 mA
higher in the AC types than in the standard type.
Ambient operating temperature: -55° to 60°C (-67° to 140°F).
Green LED ............ DC
Red LED ............... AC
Note: 1. In MY2N and MY3N, only the contact circuit is different from the illustration below. The coil terminals 10 and 11 of MY3N
RC Circuit
Specifications and dimensions same as the standard type with the
following exceptions.
The panel cutout dimensions are the same as those of the standard type.
However, the height is higher by 17.02 mm (0.67 in).
Note: 1. The above dimensioned drawing shows the 4-pole type. The dimensions of the 2- and 3-pole types are identical to the 4-
Socket needed
PY08, PY11, PY11QN,
PY14, PY4QN
2. Pay special attention to the polarities when using the DC type.
3. The AC coil-type is provided with a self-diagnostic function that detects a breakage in the coil.
2. Available on AC versions only.
3. Terminal arrangement/internal connections: MY2-Y is the same as the standard type; MY2N-Y is the same as the LED
become (-) and (+), respectively.
pole type.
indicator type.
Number of socket specs.
1
PYP-1
PYP-18
18
PYP-18
36
PYP-36
Terminal arrangement/Internal connections (Bottom view)
MY4N
DC coil rating type
PYP-36
Terminal arrangement/
Internal connections
(Bottom view)
AC coil rating type
MY