3100Y30J17999CJ Tyco Electronics, 3100Y30J17999CJ Datasheet

RELAY CONTACTOR 60A 120VAC QC

3100Y30J17999CJ

Manufacturer Part Number
3100Y30J17999CJ
Description
RELAY CONTACTOR 60A 120VAC QC
Manufacturer
Tyco Electronics
Series
3100, Products Unlimitedr
Datasheets

Specifications of 3100Y30J17999CJ

Relay Type
Contactor
Contact Form
3PST-NO-DM (3 Form X)
Contact Rating (current)
60A
Switching Voltage
600VAC
Coil Type
Standard
Coil Voltage
120VAC
Turn On Voltage (max)
93 VAC
Turn Off Voltage (min)
20 VAC
Mounting Type
Chassis Mount
Termination Style
Screw Terminal, .250" QC
Circuit
3PST-NO-DM (3 Form X)
Contact Rating @ Voltage
60A @ 600VAC
Control On Voltage (max)
93 VAC
Control Off Voltage (min)
20 VAC
No. Of Poles
3
Contact Configuration
3PST-NO
Relay Mounting
Panel
Coil Voltage Vac Nom
120V
Relay Terminals
Quick Connect
Nom Operating Power
140VA
Contact Voltage Ac Nom
600V
Contact Rating
60 A
Coil Termination
Screw
Contact Material
Silver Cadmium Oxide
Lead Free Status / RoHS Status
Lead free / RoHS non-compliant
Coil Current
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
9-1611019-4
832
Dimensions are shown for
reference purposes only.
Features
• 3-pole contactors.
• Industry-standard mounting plate.
• Optional interlock/auxiliary switches available.
• Manual test button is standard.
• Coil dust cover helps keep dust and dirt away from magnet and coil area.
• Double E magnet system provides optimal performance.
Contact Data @ 25°C
Material: Silver Cadmium Oxide.
Arrangements: 3 Form X (3PST-NO-DM).
Maximum Ratings: See Contact Ratings Table.
Nominal Coil Voltage
Maximum Pickup Volts
Drop-Out Volts Range
Nominal Inrush VA @ 50 Hz
Nominal Inrush VA @ 60 Hz
Nominal Sealed VA @ 50 Hz
Nominal Sealed VA @ 60 Hz
Nominal DC Resistance - Ohms
Coil Data @ 25°C
Voltage: 24 - 480 VAC, 50/60 Hz. See Coil Data Table below.
Insulation Class: UL Class B (130°C).
Duty Cycle: Continuous.
Contact Ratings
Coil Data
Amps
Load
Full
20
25
30
40
Number
Poles
of
3
3
3
3
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Voltage
240/277
240/277
240/277
240/277
Line
480
600
480
600
480
600
480
600
6 -15
6.0
24
18
60
53
5
7
Locked
Amps
Rotor
Issued 3-03 (PDF Rev. 3-04)
120
100
150
125
100
180
150
120
240
200
160
80
20 - 70
Catalog 1308242
120
180
6.0
88
60
53
5
Resistive
Specifications and availability
subject to change.
Model 98 - 3100
Definite Purpose Contactor
3-pole, 20-40 FLA
AC Coil
Environmental Data
Rating
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Temperature Range: Storage and Operating: -40°C – +65°C.
Flammability: UL 94-HB housing.
Mechanical Data
Coil Termination: Dual 0.250” (6.35 mm) quick connects, standard.
Contact Termination:
20, 25, 30 FLA Models
40 FLA Models
Arc Cover: Optional on 20-30 FLA models, standard on 40 FLA models.
Weight: 16 oz. (455 g) approximately
Amps
30
30
30
35
35
35
40
40
40
50
50
50
Type: #10-32 Screw with quad 0.250” (6.35 mm) quick connects.
Wire Size: 16-8 AWG (Stranding must be split for 8 AWG wire.)
Tightening Torque: 25 in.-lbs.
Type: Box Lug with dual 0.250” (6.35 mm) quick connects.
Wire Size: 14-4 Cu/Al AWG
Tightening Torque: 40 in.-lbs.
File E75492
File EN60947-4-1:1991
IEC 947-4-1
208/240
40 - 140
177
720
6.0
60
53
5
A 0.250” quick connect and a #6-32 screw, optional.
Voltage
110/120
200/240
480/600
110/120
200/208
240/277
110/120
200/208
240/277
110/120
200/208
240/277
480
600
480
600
480
600
Maximum Horsepower
65 - 185
277
220
950
6.0
60
53
5
Single
Phase
PRODUCTS UNLIMITED
1.5
7.5
3
2
5
2
5
3
-
-
-
-
-
-
-
-
-
-
series
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
150 - 270
3100
480
384
6.0
65
53
Phase
Three
5
7.5
7.5
7.5
10
15
20
10
10
15
20
10
10
20
25
-
-
-
-

Related parts for 3100Y30J17999CJ

3100Y30J17999CJ Summary of contents

Page 1

Features • 3-pole contactors. • Industry-standard mounting plate. • Optional interlock/auxiliary switches available. • Manual test button is standard. • Coil dust cover helps keep dust and dirt away from magnet and coil area. • Double E magnet system provides ...

Page 2

... Information” chart above. “Special” terminals are offered on a special order basis. Special order items may be subject to extended leadtimes and significant minimum order quantities. Your Tyco Electronics sales engineer must consult with the factory before providing price and availability information regarding items with these options. ...

Related keywords