ALA2F18 Panasonic Electric Works, ALA2F18 Datasheet - Page 3

RELAY PWR SLIM DPST 3A 18VDC PCB

ALA2F18

Manufacturer Part Number
ALA2F18
Description
RELAY PWR SLIM DPST 3A 18VDC PCB
Manufacturer
Panasonic Electric Works
Series
ALAr
Datasheet

Specifications of ALA2F18

Relay Type
General Purpose
Contact Form
DPST (2 Form A)
Contact Rating (current)
3A
Switching Voltage
125VAC
Coil Type
Standard
Coil Voltage
18VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
DPST (2 Form A)
Contact Rating @ Voltage
3A @ 125VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Coil Current
-
Control On Voltage (max)
-
Control Off Voltage (min)
-
125V AC
250V AC
LA (ALA)
3-(1). Coil temperature rise
Sample: ALA2F12, 6 pcs.
Measured portion: coil inside
Contact current: 0 A, 3A
5-(1). Electrical life test
(3 A 125 V AC, resistive load)
Sample: ALA2F12, 6 pcs.
Operation frequency: 20 times/min.
(ON/OFF = 1.5s: 1.5s)
Ambient temperature: 20°C
Circuit:
5-(2). Electrical life test
(5 A 250 V AC, resistive load)
Sample: ALA2PF12, 6 pcs.
Operation frequency: 20 times/min.
(ON/OFF = 1.5s: 1.5s)
Ambient temperature: 20°C
Circuit:
5-(3). Electrical life test
(UL lamp load test TV-4)
Tested sample: ALA2PF12, 6 pcs.
• Overload test
• Endurance test
Load: 6.0 A 120 V AC (60 Hz),
Inrush: 91 A
Operation frequency: 10 times/min
(ON: OFF = 1 s: 5 s)
No. of operations: 50 ope.
Load: 4A 120 V AC (60 Hz),
Inrush: 65 A
Operation frequency: 10 times/min
(ON: OFF = 1 s: 5 s)
No. of operations: 25,000 ope.
G
G
50
45
40
35
30
25
20
15
10
12V DC
12V DC
5
0
0
80
NO
NO
NO
NO
Coil applied voltage, %V
COM
COM
COM
COM
100
68°F
68°F
120
20°C 3A
70°C 3A
70°C 0A
20°C 0A
Contact
welding
detection
and Mis-
contacting
detection
circuit
Contact
welding
detection
and Mis-
contacting
detection
circuit
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
3-(2). Coil temperature rise
Sample: ALA2PF12, 6 pcs.
Measured portion: coil inside
Contact current: 0 A, 5A
Change of pick-up and drop-out voltage
Change of pick-up and drop-out voltage
Change of pick-up and drop-out voltage
100
100
100
50
45
40
35
30
25
20
15
10
80
60
40
20
80
60
40
20
80
60
40
20
5
0
0
0
0
0
0
0
0
80
Drop-out voltage
Drop-out voltage
Drop-out voltage
Pick-up voltage
Coil applied voltage, %V
Pick-up voltage
Pick-up voltage
No. of operations, ×10
No. of operations, ×10
No. of operations, ×10
100
2.5
2.5
120
4
20°C 5A
20°C 0A
70°C 5A
70°C 0A
4
4
2.5
5
5
Max.
Max.
x
Min.
Max.
Min.
x
Min.
Max.
Min.
Max.
x
Min.
Max.
Min.
x
x
x
4. Ambient temperature characteristics and coil
applied voltage
Contact current: ALA2F=3A
ALA2PF=5A
Change of contact resistance
Change of contact resistance
Change of contact resistance
200
150
100
50
50
40
30
20
10
50
40
30
20
10
50
40
30
20
10
0
0
0
0
0
0
0
0
20
Ambient temperature, °C
No. of operations, ×10
No. of operations, ×10
No. of operations, ×10
Allowable ambient temperatures
2.5
2.5
40
against % coil voltages
(max. inside the coil
temperature set as
115°C 239°F)
60
4
4
4
2.5
80
5
5
Max.
x
Min.
Max.
x
Min.
Max.
Min.
x

Related parts for ALA2F18