ALZ12B24 Panasonic Electric Works, ALZ12B24 Datasheet
ALZ12B24
Specifications of ALZ12B24
Available stocks
Related parts for ALZ12B24
ALZ12B24 Summary of contents
Page 1
... B and 105°C 221°F for the class F. 4. Low operating power Power saved with a nominal operating power of only 400 mW. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. VDE LZ RELAYS (ALZ) 5. Conforms to the various safety standards: UL/C-UL, VDE approved. ...
Page 2
... Humidity 85% R.H. (Not freezing and condensing at low temperature) 20 times/min. (at nominal switching capacity) Approx .42 oz Sealed type Class B insulation Part No. ALZ12B05W ALZ12B09W ALZ12B12W ALZ12B18W ALZ12B24W ALZ12B48W ALZ52B05W ALZ52B09W ALZ52B12W ALZ52B18W ALZ52B24W ALZ52B48W Nominal operating Coil resistance power [±10%] (at 20°C 68°F) (at 20°C 68°F) 63Ω ...
Page 3
... Tolerance ±0.1 ±0.2 .039inch less than 3mm .118 inch: ±0.3 .118 inch: All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. 3. Coil temperature rise Sample: ALZ11F12, 5pcs. Measured portion: coil inside Contact current 100 105 110 115 ...
Page 4
... In order to obtain the full rated life cycles, the relay should be properly vented by removing the vent nib after the soldering/ washing process. Vent nib For Cautions for Use. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. Contact rating VDE (Certified) File No. Contact rating File No. ...