ALZ11F24 Panasonic Electric Works, ALZ11F24 Datasheet

RELAY POWER 16A 24VDC FLUX-RES

ALZ11F24

Manufacturer Part Number
ALZ11F24
Description
RELAY POWER 16A 24VDC FLUX-RES
Manufacturer
Panasonic Electric Works
Series
ALZr
Type
Power Relayr
Datasheets

Specifications of ALZ11F24

Relay Type
General Purpose
Contact Form
SPDT (1 Form C)
Contact Rating (current)
16A
Switching Voltage
250VAC
Coil Type
Standard
Coil Current
16.7mA
Coil Voltage
24VDC
Turn On Voltage (max)
16.8 VDC
Turn Off Voltage (min)
2.4 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
16A @ 250VAC
Control On Voltage (max)
16.8 VDC
Control Off Voltage (min)
2.4 VDC
Relay Construction
Non-Latching
Contact Arrangement
SPDT
Coil Voltage Dc
24V
Voltage Rating (vac)
440V
Dropout Volt (min)
2.4VDCV
Coil Resistance
1.44kohm
Pick-up Voltage (max)
16.8VDC
Maximum Power Rating
4KVA
Operate Time
15ms
Contact Current Rating
16A
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Flux Resistant
Product Height (mm)
15.7mm
Product Depth (mm)
12.5mm
Product Length (mm)
28.8mm
Operating Temp Range
-40C to 105C
Pin Count
8
Mounting Style
Through Hole
Package / Case
DIP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ALZ11F24
Manufacturer:
MICRON
Quantity:
10 000
LZ (ALZ)
ORDERING INFORMATION
LZ relays
Contact arrangement
1: 1 Form C
5: 1 Form A (New PC board terminal)
Protective construction
1: Flux-resistant type
2: Sealed type
Coil insulation class
B:
F:
Nominal coil voltage (DC)
05: 5 V
09: 9 V
12: 12 V
Flame resistance and tracking resistance
Nil:
T:
Packing style
W: Carton packing
Notes: 1. Certified by UL/C-UL and VDE
Compliance with RoHS Directive
Class B insulation
Class F insulation
EN60335-1 (Conform)
2. Tube packing type is also available. Please consult us.
18: 18 V
24: 24 V
48: 48 V
ALZ
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
FEATURES
1. Low profile type with height of 15.7
mm
Slim, low profile type with dimensions of
28.8 (L) × 12.5 (W) × 15.7 (H) mm
1.134 (L) × .492 (W) × .618 (H) inch.
2. High insulation resistance
Superior insulation characteristics have
been achieved by maintaining an
insulation distance between coil and
contacts of at least 10 mm for both
creepage distance and clearances.
Furthermore, anti-surge voltage is 10 kV
and higher. (Supports European
reinforced insulation requirement.)
3. Superior heat resistance
Can be used in ambient temperatures up
to 85°C
221°F
4. Low operating power
Power saved with a nominal operating
power of only 400 mW.
Low profile: 15.7mm height
1a/1c 16A power relay
for the class F.
185°F
for the class B and 105°C
5. Conforms to the various safety
standards:
UL/C-UL, VDE approved.
6. Superior heat resistance and
tracking resistance
EN60335-1 GWT compliant (Tested by
VDE) type available
TYPICAL APPLICATIONS
1) Household electrical appliances
TV, CATV, Audio equipment, Microwave
ovens, and Heaters, etc.
2) Office equipment
Copy machines, Packaged air
conditioners, and Vending machines
3) Industrial equipment
Machine tools, Robots, and Temperature
controllers
LZ RELAYS (ALZ)
VDE

Related parts for ALZ11F24

ALZ11F24 Summary of contents

Page 1

... B and 105°C 221°F for the class F. 4. Low operating power Power saved with a nominal operating power of only 400 mW. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. VDE LZ RELAYS (ALZ) 5. Conforms to the various safety standards: UL/C-UL, VDE approved. ...

Page 2

... All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. Flux-resistant type Class B insulation Class F insulation Part No. Part No. ALZ11B05W ALZ11F05W ALZ11B09W ALZ11F09W ALZ11B12W ALZ11F12W ALZ11B18W ALZ11F18W ALZ11B24W ALZ11F24W ALZ11B48W ALZ11F48W ALZ51B05W ALZ51F05W ALZ51B09W ALZ51F09W ALZ51B12W ALZ51F12W ALZ51B18W ALZ51F18W ALZ51B24W ALZ51F24W ALZ51B48W ALZ51F48W ...

Page 3

... Tolerance ±0.1 ±0.2 .039inch less than 3mm .118 inch: ±0.3 .118 inch: All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. 3. Coil temperature rise Sample: ALZ11F12, 5pcs. Measured portion: coil inside Contact current 100 105 110 115 ...

Page 4

... In order to obtain the full rated life cycles, the relay should be properly vented by removing the vent nib after the soldering/ washing process. Vent nib For Cautions for Use. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. Contact rating VDE (Certified) File No. Contact rating File No. ...

Related keywords