DSP2A-DC5V-R Panasonic Electric Works, DSP2A-DC5V-R Datasheet - Page 7

RELAY MINI POWER 5VDC PCB

DSP2A-DC5V-R

Manufacturer Part Number
DSP2A-DC5V-R
Description
RELAY MINI POWER 5VDC PCB
Manufacturer
Panasonic Electric Works
Series
DSPr
Datasheet

Specifications of DSP2A-DC5V-R

Relay Type
General Purpose
Contact Form
DPST (2 Form A)
Contact Rating (current)
5A
Switching Voltage
250VAC
Coil Type
Standard
Coil Current
60mA
Coil Voltage
5VDC
Turn On Voltage (max)
4 VDC
Turn Off Voltage (min)
0.5 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
DPST (2 Form A)
Contact Rating @ Voltage
5A @ 250VAC
Control On Voltage (max)
4 VDC
Control Off Voltage (min)
0.5 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
DIMENSIONS
FIXING AND REMOVAL METHOD
1. Match the direction of relay and socket.
2. Both ends of relays are fixed so tightly
that the socket hooks on the top surface
of relays.
Compliance with RoHS Directive
CAD Data
.224 .012
5.7 0.3
.669 .024
.433 .024
17 0.6
11 0.6
.012 .004
0.3 0.1
.146
3.7
Good
.300 .012 .400 .012
7.62 0.3 10.16 0.3
External dimensions
.906 .024
23 0.6
(mm inch)
No good
0.8 0.1
.031 .004
2.54 0.3
.100 .012
2.61
.103
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
7.62 0.3
.300 .012
The CAD data of the products with a
0.65 0.1
.026 .004
TYPES AND APPLICABLE RELAYS
SPECIFICATIONS
3. Remove the relay, applying force in the
direction shown below.
Applicable relays
DSP1a relays
DSP1a-L2 relays
DSP1 relays
DSP1-L2 relays
DSP2a relays
DSP2a-L2 relays
Breakdown voltage
Insulation resistance
Heat resistance
Max. continuous current
DSP1a-PS, DSP1a-PSL2
Terminal No.2 and 15 are for
DSP1a-PSL2 only.
ACCESSORIES
Item
8
Type No.
1.2 dia.
047 dia.
CAD Data
5
15
3,000 Vrms between terminals
(Except for the portion between coil terminals)
1,000 M between terminals at 500 V
150 C for 1 hour
8 A
2
DSP1a-PS
2.54
.100
PC board pattern (Bottom view)
16
1
mark can be downloaded from: http://panasonic-electric-works.net/ac
OK
For DSP1a
2.54
.100
DSP1a-PSL2
4. In case there is not enough space for
finger to pick relay up, use screw drivers
in the way shown below.
Notes: 1. Exercise care when removing relays. If
SOCKETS FOR
DS-P RELAYS
OK
OK
DSP2a-PS, DSP2a-PSL2
Terminal No.2 and 15 are for
DSP2a-PSL2 only.
2. It is hazardous to use IC chip sockets.
Specifications
greater than necessary force is applied at
the socket hooks, deformation may alter the
dimensions so that the hook will no longer
catch, and other damage may also occur.
9
8
DSP2a-PS
For DSP1a, DSP1, DSP2a
1.2 dia.
047 dia.
12
5
OK
OK
OK
15
2
2.54
.100
16
1
DSP2a-PSL2
OK
OK
OK
OK
OK
OK
DSP
2.54
.100

Related parts for DSP2A-DC5V-R