CR5395-EL-24D-110-X-CD-ELR-I CR Magnetics Inc, CR5395-EL-24D-110-X-CD-ELR-I Datasheet - Page 2

no-image

CR5395-EL-24D-110-X-CD-ELR-I

Manufacturer Part Number
CR5395-EL-24D-110-X-CD-ELR-I
Description
CURRENT SENSING RELAY
Manufacturer
CR Magnetics Inc
Series
CR5395r

Specifications of CR5395-EL-24D-110-X-CD-ELR-I

Relay Type
Current Sense
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
10A @ 240VAC
Coil Type
Standard
Coil Voltage
24VDC
Control On Voltage (max)
Adjustable
Control Off Voltage (min)
Adjustable
Mounting Type
Chassis Mount
Termination Style
Quick Connect - .250" (6.3mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Coil Current
-
Other names
Q3812469
TRIP STATUS
EH - Energized on High, trips
when sense current is above trip
point and returns to non-trip
status when sense current is
below the trip point.
EL - Energized on Low, trips
when sense current is below trip
point and returns to non-trip
status when sense current is
above the trip point.
LH - Latch on High, trips when
sense current is above trip point
and remains tripped until
supply power is removed.
LL - Latch on Low, trips when
sense current is below trip point
and remains tripped until supply
power is removed.
Shown with Internal Transformer Option (-l)
SUPPLY POWER TERMINALS
1/4" MALE QUICK CONNECT
Another HUNTINGTON ELECTRIC Company
TYPICAL 2 PLACES
2 1/8 (54)
MAX.
7/8 (22.2)
CRDCS -
3 1/2
(88.9)
.50 (12.7) DIA.
CR5395 -
OUTLINE DRAWING
2 15/16
9/32 (7.14)
(74.6)
050 - 1.60 dia. Window
100 - 2.70 dia. Window
200 - 3.00 dia. Window
NC NO COM
1 15/16 (49.2)
1/4" MALE QUICK CONNECT
OUTPUT RELAY TERMINALS
TYPICAL 3 PLACES
2 1/2 (63.5)
SUPPLY VOLTAGE
12D - 12 VDC
ACV - 85 to 265 VAC
24D - 24 VDC ±10%
CR Magnetics, Inc. 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119
Web: http://www.crmagnetics.com
TIME-ON DELAY,
TURN CLOCKWISE
9/32 (7.14)
3/16 DIA. MOUNTING H
TO INCREASE
TYPICAL 2 PLACES
INDICATING LED
"ON" WHEN RELAY
IS TRIPPED
Available with external ring sensors
range. Contact Factory for details.
capable of over 1000A of sensing
EXTERNAL CURRENT SENSING TRANSFORMER
-
The trip ranges shown are for
one wire pass through the
window opening. The trip range
may be proportionally lowered
with additional wire passes
through the window.
PART NUMBER
101 - 10 to 100 ADC
660 - 6.0 to 60 ADC
110 - 1.0 to 10 ADC
330 - 3.0 to 30 ADC
Shown with Remote Current
Transformer Option (-R)
TRIP RANGE
-
-
71
NC NO COM
when the output energizes. The ranges are
greater.
TRIP POINT DIAL
(Specify value of fixed
trippoint with order)
Time-on delay is the time from when the relay trips to
guaranteed minimum, actual range may be slightly
-3.30 trip range shown
-
CD - Calibrated Dial
FP - Fixed Trip Point
- CD
Direct Current Sensing Relay
dial provided with
TRIP ON DELAY
A - .5 to 6 Sec.
B - 2 to 25 Sec.
C - .1 - 1 Sec.
X - none
No adjustment
the fixed set
point option
- FP
-
0.74[18.80mm](-050)
1.65[42.00mm](-100)
1.85[47.00mm(-200)
1.60 [40.64mm](-050)
2.70 [68.60mm](-100)
3.00 [76.20mm](-200)
E-mail: sales@crmagnetics.com
Electromechanical
REMOTE DC CURRENT SENSOR
CRDCS - Series
ELR
Relay
I - INTERNAL TRANSFORMER
R - REMOTE TRANSFORMER
NC NO COM
OUTPUT OPTIONS
-
NPN Transistor
CR5395 Series
Optoisolated
NPN
10" [304.8mm](-050)
12" [304.8mm](-100 & -200)
Triac, Zero Crossing
0.56 [14.24mm](-050)
0.70 [17.80mm](-100)
1.85 [47.00mm](-200)
Optoisolated
TRC
E