VKP-15F42 Tyco Electronics, VKP-15F42 Datasheet - Page 3

RELAY PWR SPDT 40A 12VDC OPEN

VKP-15F42

Manufacturer Part Number
VKP-15F42
Description
RELAY PWR SPDT 40A 12VDC OPEN
Manufacturer
Tyco Electronics
Series
VKPr
Datasheet

Specifications of VKP-15F42

Relay Type
Automotive
Contact Form
SPDT (1 Form C)
Contact Rating (current)
40A
Switching Voltage
12VDC
Coil Type
Standard
Coil Current
133.3mA
Coil Voltage
12VDC
Turn On Voltage (max)
6.8 VDC
Turn Off Voltage (min)
1.2 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
40A @ 12VDC
Control On Voltage (max)
6.8 VDC
Control Off Voltage (min)
1.2 VDC
Coil Voltage Vdc Nom
12V
Contact Current Max
30A
Contact Voltage Dc Nom
12V
Coil Resistance
90ohm
Contact Configuration
SPDT
Relay Mounting
PCB
External Height
18.2mm
External Width
19mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
1393278-1
PB313
158
Contact Data
Typical areas of application
Contact configuration
Circuit symbol
(see also Pin assignment)
Rated voltage
Rated current
Limiting continuous current
Contact material
Max. switching voltage/power
Max. switching current
On
Off
Min. recommended current
Voltage drop at 10 A (initial)
Mechanical endurance (without load)
Electrical endurance
(example of resistive load)
1)
2)
Load Limit Curve
Circuit Diagram
1 Make contact/1 Form A
Inrush current for lamp load.
See load limit curve.
1)
2)
12
10
60
50
30
20
75
40
0.5
TE1091-B1
1
2
Switching Current (A)
3
105°C
23°C
85°C
4
PCB Relays
Single Relays
VKP (Open – Sealed)
All specifications subject to change. Consult Tyco Electronics for latest specifications.
1 Changeover contact/1 Form C
5
7
1 Make contact/
Typ. 15 mV
1 Form A
10
100 A
32 A
40 A
32 A
25 A
60 A
TE1086-A1
Resistive/inductive loads
AgNi0.15 (VKP-***42)
20
ECR2128-U
30
40
1 Changeover contact/
Typ. 20/15 mV
Safe breaking, arc extinguished (normally
open contact) for resistive loads.
30 A/100 A
30 A/60 A
1 Form C
30/40 A
25/32 A
15/25 A
25/32 A
NC/NO
NC/NO
C
3
4
10
5
5
operations at 40 A, 14 V,
See load limit curve
> 10
on NO contact
1 A at 5 V
7
12 V
operations
1 Make contact/
Typ. 20 mV
1 Form A
180 A
32 A
40 A
32 A
25 A
60 A
High inrush, lamp and capacitive loads
AgSnO
2
(VKP-***52)
1 Changeover contact/
Typ. 25/20 mV
Catalog 1308028-2
30 A/180 A
30 A/60 A
1 Form C
25/32 A
30/40 A
25/32 A
15/25 A
NC/NO
NC/NO
C
3
4
Revised 6-2009
5