PM-17DY-12 Tyco Electronics, PM-17DY-12 Datasheet - Page 23

no-image

PM-17DY-12

Manufacturer Part Number
PM-17DY-12
Description
RELAY HVY DTY 25A 4PDT 12VDC
Manufacturer
Tyco Electronics
Series
PMr
Datasheet

Specifications of PM-17DY-12

Relay Type
General Purpose
Contact Form
4PDT (4 Form C)
Contact Rating (current)
25A
Switching Voltage
277VAC
Coil Type
Standard
Coil Current
364mA
Coil Voltage
12VDC
Turn On Voltage (max)
9 VDC
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Circuit
4PDT (4 Form C)
Contact Rating @ Voltage
25A @ 277VAC
Control On Voltage (max)
9 VDC
Lead Free Status / RoHS Status
Lead free / RoHS non-compliant
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
5-1393126-0
PB507
"W6 and W9" Series magnetic-hydraulic circuit breakers are de-
signed to pass safe surge currents and momentary overloads, but to
trip on dangerous overloads. Units are offered with various trip time
delays Between the must-trip values of 101% to 125% of rating,
these breakers are temperature stable from -40oC to 85oC. They
will hold 100% of their rated load when installed in standard panel
mount positions.
Calibration: Breaker will continuously carry 100% of rated load. It may trip between
101% and 124% of rated load but must trip at 125%.
Max. Operating Voltages: 277 AC; 64VDC
Auxiliary Switch Rating: SPDT Common: 5A@ 125/250VAC; 1A@ 50VDC
Reset Time: Instantaneous.
*
Single Pole
Two Pole
Three Pole
W69-X2Q12-5
W69-X2Q12-10
W69-X2Q12-15
W69-X2Q12-20
W69-X2Q12-25
W69-X2Q12-30
W68-X2Q110-20
W68-X2Q110-30
W67-A2Q12-10*
Type & AMPS
W67-X2Q12-10
W67-X2Q12-15
W67-X2Q12-20
W67-X2Q12-30
W67-X2Q13-10
W67-X2Q13-15
W67-X2Q13-20
W67-X2Q13-25
W67-X2Q50-10
W67-X2Q52-10
W67-X2Q52-30
W68-X2Q12-10
W68-X2Q12-15
W68-X2Q12-20
W68-X2Q12-25
W68-X2Q12-30
W68-X2Q13-15
W67-A2Q12-5*
Single Pole W Aux. Switch
W67-X2Q10-3
W67-X2Q10-5
W67-X2Q12-2
W67-X2Q12-3
W67-X2Q12-5
W67-X2Q12-7
W67-X2Q13-2
W67-X2Q13-5
W67-X2Q52-5
W68-X2Q12-2
W68-X2Q12-3
W68-X2Q12-5
Mfr.’s
MINI-MAG BREAKERS
W67, W68, W69
Voltage
DC
AC
AC
AC
DC
AC
AC
AC
AC
AC
GENERAL INFORMATION
ENGINEERING DATA
MAGNETIC/HYDRAULIC CIRCUIT BREAKERS W67,
W68, W69, W91, W92,W93.
@200% OF
TRIP TIME
.15-1.5sec
.15-1.5sec
2.2-20sec
2.2-20sec
2.2-20sec
2.2-20sec
2.2-20sec
9-100sec
RATING
30ms
30ms
Single Pole
Two Pole
Three Pole
W
Type & AMPS
W91-X152-10
W91-X152-15
W91-X152-20
W91-X152-30
W91-X152-40
W91-X152-50
W91-X112-10
W91-X112-15
W91-X112-20
W91-X112-40
W91-X112-50
W91-X113-10
W91-X113-15
W93-X112-10
W93-X112-15
W93-X112-20
W93-X112-25
W93-X112-30
W93-X112-40
W93-X112-50
W92-X112-15
W92-X112-40
W92-X112-10
W92-X112-20
W92-X112-25
W92-X112-30
W92-X112-50
W91-X112-2
W91-X113-5
W91-X152-5
W91-X112-1
W91-X112-3
W91-X112-5
W91-X112-7
W93-X112-5
STANDARD SIZE BREAKERS
CATALOG NUMBERING EXPLINATION
W92-X112-1
W92-X112-2
W92-X112-3
W92-X112-5
W92-X112-7
Mfr.’s
67
X
CIRCUIT BREAKERS
W91, W92, W93
2
Voltage
Q
AC
AC
DC
AC
AC
1
2
.75"x2.5"x2.1"d
.75"x2.0"x1.64d
@200% OF
Single Pole
TRIP TIME
W 9 Series
.15-1.5sec
2.2-20sec
2.2-20sec
2.2-20sec
2.2-20sec
Single Pole
RATING
W 6 Series
20
FUSEHOLDER-TYPE THERMAL
BREAKER W28 SERIES MOUNT
SAME AS PANEL MOUNTED FUSE-
HOLDER
"W" Series breakers are UL 1077 Recognized as
Supplementary Protectors, File E69543, and CSA
Certified as Appliance Component Protectors, File
LR30671.
Certificate of Suitablity CS2190N as Supplementary
Equipment Protectors by the Energy Authority of
New South Wales, Australia. W28 breakers are also
DEMKO
approved. VDE approved for use in office equipment
and provides 8mm contact spacing.
Calibration: Will continuously carry 100% of rating.
3-15 amp models- may trip between 101% and
134%, but must trip at 135% of rating within one hour
at 25˚C 0.25-2 amp models- may trip between 101%
and 174% but must trip at 175% of rating within one
hour @ 25˚C
Dielectric Strength: Over 1,500 volts RMS
Max. Operating Vo l t a g e s : 32 VDC; 250VA C ,
50/60Hz
Interrupt Capacity: 1,000 amps at 250 VA C ,
50/60Hz. and 32V DC in accordance with UL stan-
dard 1077.
Resettable Overload Capacity: Ten times rated cur-
rent.
Reset time: 0.25-2 amp models 180 seconds, max-
imum 3-15 models, 10-60 seconds.
W28-XQ1A-1
W28-XQ1A-2
W28-XQ1A-15
W28-XQ1A-0.25
W28-XQ1A-0.50
W28-XQ1A-3
W28-XQ1A-4
W28-XQ1A-5
W28-XQ1A-6
W28-XQ1A-7
W28-XQ1A-8
W28-XQ1A-10
W28-XQ1A-12
Mfr.’s
Type
(Denmark)
W28
ENGINEERING DATA
breakers have
IN AMPS
RATING
W=6/32 Mounting Threads
67-Single Pole
68-Two Pole
69-Three Pole
91-Single Pole
92-Two Pole
93-Three Pole
X -Series Trip
A-Series Trip With
Auxilary Switch
1-Black Toggle
2-White Toggle
Q-.250" Quick Connect -
(W9 Series have 10/32 studs)
1=277VAC 50/60Hz
277/480 VAC, 3ø-WYE
5=65 VDC
0=Instantaneous
2=Standard
3=Short Delay
From.025--50=Amps
.050
0.25
10
12
15
2
3
5
6
8
1
4
7
and
SEV
@200% OF
TRIPTIME
RATING
been
4.5-28
2.2-15
(Switzerland)
SEC.
SEC.
issued

Related parts for PM-17DY-12