Page 1
... Contact Protective arrangement construction 1a: 1 Form A F: Flux-resistant type Note: Standard packing Carton: 100 pcs. Case: 500 pcs. UL/CSA, TV-5 (only for TV type) approved type is standard. JZ-RELAYS .866 .551 .457 inch Characteristics ( 50% Relative humidity) Max. operating speed Initial insulation resistance* 1 Min. 100 M at 500 V DC ...
Page 2
... TYPES AND COIL DATA ( Standard type Nominal voltage, Pick-up voltage, Part No (max.) JZ1aF-5V 5 JZ1aF-6V 6 JZ1aF-9V 9 JZ1aF-12V 12 JZ1aF-18V 18 JZ1aF-24V 24 2) High sensitivity type Nominal voltage, Pick-up voltage, Part No (max.) JZ1aFS-5V 5 JZ1aFS-6V 6 JZ1aFS-9V 9 JZ1aFS-12V 12 JZ1aFS-18V 18 JZ1aFS-24V 24 DIMENSIONS 5.08 .200 7.62 .300 2.11 .083 REFERENCE DATA • ...
Page 3
... Noise wave form (Applied voltage wave form to the contact) 10,000 9,500 8,000 6,000 4,000 2,000 Time, s 2-(1). Operate/Release time (Standard type) Sample: JZ1aF-12V- Max. x – 2 Min 100 120 130 Coil applied voltage, %V 4.-(2) Ambient temperature vs. coil applied voltage (High sensitivity type) ...
Page 4
... Operating (ON:OFF = (ON:OFF = speed 1s:5s) 1s:5s) No ope. 25,000 ope. operations 5-(2). Electrical life test (Condenser load) Tested sample: JZ1aF-12V-TV, 6 pcs. Load 6.4 A, Inrush max. 139 A Operating speed: 20 cpm (ON:OFF = 1 s:2 s) Ambient temperature Circuit: Changing coil Mis-contacting 12 m 200 H DC detection ...
Page 5
... JZ 5-(3). Electrical life test (TV power source) Tested sample: JZ1aF-12V-TV, 10 pcs. Load: AC 100 V TV power source Inrush: 100 A max.; Steady: 5.0 A Operating speed: 20 cpm (ON:OFF = 1 s:2 s) Ambient temperature 104 F95% R.H. Circuit: Mis-contacting AC PC detection 100 V board Contact welding detection 40 C 95%R.H. ...