TQ2-12V Panasonic Electric Works, TQ2-12V Datasheet - Page 5

RELAY STD DPDT 1A 12VDC PC MNT

TQ2-12V

Manufacturer Part Number
TQ2-12V
Description
RELAY STD DPDT 1A 12VDC PC MNT
Manufacturer
Panasonic Electric Works
Series
TQr
Type
General Purpose Relayr
Datasheets

Specifications of TQ2-12V

Relay Type
Telecom
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
1A @ 30VDC
Coil Type
Standard
Coil Current
11.7mA
Coil Voltage
12VDC
Control On Voltage (max)
9 VDC
Control Off Voltage (min)
1.2 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Brand/series
TQ Series
Contact Form
DPDT
Current, Rating
0.5⁄1 AAC⁄ADC
Diameter, Mounting
0.039 in. Dia. (Hole)
Dimensions
0.551 in. L x 0.354 in. W x 0.197in. + 0.016 in. - 0.008 in. H
Function
General Purpose
Latch Type
Single Side Stable
Material, Contact
Gold-Clad Silver
Number Of Pins
10
Standards
UL, CSA
Termination
Solder
Voltage, Control
12 VDC
Voltage, Rating
125 VAC
Surge Voltage Withstand
1500 V FCC Part 68
Relay Construction
Non-Latching
Contact Arrangement
DPDT
Coil Voltage Dc
12V
Voltage Rating (vdc)
110V
Voltage Rating (vac)
125V
Dropout Volt (min)
1.2VDCV
Coil Resistance
1.028kohm
Pick-up Voltage (max)
9VDC
Maximum Power Rating
30W/62.5VA
Operate Time
3ms
Contact Current Rating
1A
Contact Material
Ag/Au Clad
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Unsealed
Product Height (mm)
5mm
Product Depth (mm)
9mm
Product Length (mm)
14mm
Operating Temp Range
-40C to 70C
Pin Count
8
Mounting Style
Through Hole
Package / Case
DIP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-1002
255-1002-5
255-1002
TQ2E-12V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TQ2-12V
Manufacturer:
NAIS/PANASONIC
Quantity:
20 000
Part Number:
TQ2-12V
Manufacturer:
OMRON
Quantity:
30 000
Part Number:
TQ2-12V
Manufacturer:
Panasonic
Quantity:
5
Part Number:
TQ2-12V
0
Company:
Part Number:
TQ2-12V
Quantity:
15 655
Part Number:
TQ2-12V ATQ203
Manufacturer:
PANASONIC/松下
Quantity:
20 000
Part Number:
TQ2-12VATQ203
Manufacturer:
PANASONIC/松下
Quantity:
20 000
[M.B.B. type]
*Pulse drive (JIS C 5442-1986)
2. Specifications
Notes: *1 AC is standard (B.B.M) type only.
■ Surface-mount terminal
1. Coil data
1) Single side stable
Contact
Rating
Electrical
characteristics
Mechanical
characteristics
Expected life
Conditions
Unit weight
Characteristics
Nominal coil
Nominal coil
4.5V DC
1.5V DC
4.5V DC
12V DC
24V DC
12V DC
24V DC
48V DC
voltage
voltage
3V DC
5V DC
6V DC
9V DC
3V DC
5V DC
6V DC
9V DC
*2 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
*3 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT.
actual load. (SX relays are available for low level load switching [10V DC, 10mA max. level])
Arrangement
Initial contact resistance, max.
Contact material
Nominal switching capacity
Max. switching power
Max. switching voltage
Max. switching current
Min. switching capacity (Reference value)*
Nominal
operating power
Insulation resistance (Initial)
Breakdown
voltage (Initial)
Temperature rise (at 20 C
Operate time [Set time] (at 20 C
Release time [Reset time] (at 20 C
Shock
resistance
Vibration
resistance
Mechanical (at 180 cpm)
Electrical (at 20 cpm)
Conditions for operation, transport and
storage*
Max. operating speed (at rated load)
nominal voltage*
nominal voltage*
80%V or less of
75%V or less of
Pick-up voltage
Pick-up voltage
(at 20 C
(at 20 C
(Initial)
(Initial)
3
68
68
F)
F)
Single side stable
1 coil latching
2 coil latching
Between open contacts
Between contact and coil
Between contact sets
Functional
Destructive
Functional
Destructive
Item
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
68
10%V or more of
10%V or more of
Drop-out voltage
nominal voltage*
Drop-out voltage
nominal voltage*
(at 20 C
(at 20 C
F)
(Initial)
(Initial)
68
68
F)
68
68
F)
F)
F)
2
Max. 50 C (By resistive method, nominal coil voltage applied to the coil; contact carrying current: 1A.)
Standard (B.B.M) type: 140 mW (3 to 12 V DC),
[ 10%] (at 20 C
100 mW (3 to 12 V DC), 150 mW (24 V DC)
200 mW (3 to 12 V DC), 300 mW (24 V DC)
Max. 3 ms [Max. 3 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 3 ms [Max. 3 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Nominal operating
Standard (B.B.M) type: Min. 2 10
Nominal operating
200 mW (24 V DC), 300 mW (48 V DC)
(at 20 C
66.7mA
44.4mA
33.3mA
22.2mA
16.7mA
93.8mA
46.7mA
28.1mA
23.3mA
15.5mA
11.7mA
current
current
8.3mA
8.3mA
6.3mA
40mA
2 Form C, 2 Form D (M.B.B.)
31mA
Min. 490 m/s
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
M.B.B. type: 200 mW
Approx. 1.5 g
68
Standard (B.B.M) type: 750 Vrms for 1min. (Detection current: 10 mA),
Measurement at same location as “Initial breakdown voltage” section.
F)
68
10 to 55 Hz at double amplitude of 3 mm (Detection time: 10 s.)
M.B.B. type: 300 Vrms for 1 min. (Detection current: 10 mA)
F)
Ambient temperature: –40 C to +70 C
Ambient temperature: –40 C to +50 C
Standard (B.B.M) type: Min. 10
Min. 980 m/s
2
1,000 Vrms for 1min. (Detection current: 10 mA)
1,000 Vrms for 1min. (Detection current: 10 mA)
[ 10%] (at 20 C
1 A 30 V DC, 0.5 A 125 V AC*
(Half-wave pulse of sine wave: 11 ms; detection time: 10 s.)
[ 10%] (at 20 C
.053 oz
M.B.B. type: Min. 10
30 W (DC), 62.5 V A (AC)*
Max. 50m (By voltage drop 6 V DC 1A)
10 to 55 Hz at double amplitude of 5 mm
Coil resistance
Coil resistance
2,880
1,028
2,880
7,680
64.3
101
125
180
405
720
145
178
257
579
45
Min. 1,000M
16
5
2
(1 A 30 V DC resistive), Min. 10
(Half-wave pulse of sine wave: 6 ms.)
Standard (B.B.M) type:
110 V DC, 125 V AC*
10 A 10mV DC
(without diode)
Specifications
68
68
M.B.B. type:
Ag+Au clad
20 cpm
F)
F)
5
1 A
(1 A 30 V DC resistive)
(at 500V DC)
8
280 mW (3 to 24 V DC), 400 mW (48 V DC)
Nominal operating
Nominal operating
, M.B.B. type: Min. 10
1
(resistive load)
1
(resistive load)
200mW
140mW
200mW
300mW
1
power
–40 F to +158
–40 F to +122
power
Approx. 3 g
5
(0.5 A 125 V AC resistive)
4 Form C
200 mW
400 mW
7
F;
F;
.106 oz.
Max. applied voltage
Max. applied voltage
nominal voltage
nominal voltage
nominal voltage
(at 20 C
(at 20 C
150%V of
150%V of
120%V of
68
68
F)
F)
TQ

Related parts for TQ2-12V