G6H-2 DC3 Omron, G6H-2 DC3 Datasheet - Page 8

RELAY MINI PC MNT DPDT 1A 3VDC

G6H-2 DC3

Manufacturer Part Number
G6H-2 DC3
Description
RELAY MINI PC MNT DPDT 1A 3VDC
Manufacturer
Omron
Series
G6Hr
Datasheets

Specifications of G6H-2 DC3

Relay Type
Telecom
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
1A @ 30VDC
Coil Type
Standard
Coil Current
46.7mA
Coil Voltage
3VDC
Control On Voltage (max)
2.25 VDC
Control Off Voltage (min)
0.3 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Contact Form
DPDT
Current, Rating
0.5⁄1 AAC⁄ADC
Function
Sensitive
Number Of Pins
10
Power, Rating
62.5⁄33 VA⁄W
Standards
UL, CSA, RoHS
Voltage, Control
3 VDC
Voltage, Rating
125 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G6H-2-DC3
G6H-2-DC3
G6H2DC3
Z2540
Precautions
Long-term Continuously ON Contacts
Using the Relay in a circuit where the Relay will be ON continuously
for long periods (without switching) can lead to unstable contacts
because the heat generated by the coil itself will affect the insulation,
causing a film to develop on the contact surfaces. We recommend
using a latching relay (magnetic-holding relay) in this kind of circuit. If
a single-side stable model must be used in this kind of circuit, we rec-
ommend using a fail-safe circuit design that provides protection
against contact failure or coil burnout.
Claw Securing Force During Automatic Mounting
During automatic insertion of Relays, be sure to set the securing
force of each claw to the following so that the Relay’s characteristics
will be maintained.
56
Direction A: 1.96 N max.
Direction B: 4.90 N max.
Direction C: 1.96 N max.
A
C
B
Low Signal Relay
G6H
DISCONTINUED
Relay Handling
Use the Relay as soon as possible after opening the moisture-proof
package. If the Relay is left for a long time after opening the mois-
ture-proof package, the appearance may deteriorate and seal failure
may occur after the solder mounting process. To store the Relay after
opening the moisture-proof package, place it into the original pack-
age and seal the package with adhesive tape.
When washing the product after soldering the Relay to a PCB, use a
water-based solvent or alcohol-based solvent, and keep the solvent
temperature to less than 40°C. Do not put the Relay in a cold clean-
ing bath immediately after soldering.

Related parts for G6H-2 DC3