SPECIFICATIONS
Contact
Note:
Remarks
* Specifications will vary with foreign standards certification ratings.
*
*
*
*
*
*
*
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1A)
Contact material
Rating
Nominal
operating
power
Expected
life (min.
opera-
tions)
1
2
3
4
5
6
7
1 This value can change due to the switching frequency, environmental conditions,
Measurement at same location as “Initial breakdown voltage” section.
By resistive method, nominal voltage applied to the coil; contact carrying current:
1 A.
Nominal voltage applied to the coil, excluding contact bounce time.
Nominal voltage applied to the coil, excluding contact bounce time without diode.
Half-wave pulse of sine wave: 11 ms; detection time: 10 s.
Half-wave pulse of sine wave: 6 ms.
Detection time: 10 s.
and desired reliability level, therefore it is recommended to check this with the
actual load. (SX relays are available for low level load switching [10 µA 1 mV DC
– 10 mA 10 V DC])
Nominal switching capacity
(resistive load)
Max. switching power
(resistive load)
Max. switching voltage
Max. switching current
Min. switching capacity 1
Single side stable
1 coil latching
2 coil latching
Mechanical (at 180 cpm)
Electrical
(at 20 cpm)
(1 A 30 V DC
resistive)
1.051
26.7
1 A 30 V DC
resistive
0.5 A 125 V AC
resistive
.354
9
5
.197
+0.4
–0.2
+.016
–.008
(3 to 12 V DC)
(3 to 12 V DC)
(3 to 12 V DC)
(24 V DC)
(48 V DC)
(24 V DC)
(24 V DC)
2 Form C
140 mW
200 mW
300 mW
100 mW
150 mW
200 mW
300 mW
110 V DC, 125 V AC
0.5 A 125 V AC
30 W, 62.5 V A
(B.B.M) type
1 A 30 V DC
Standard
.551
2 10
14
10 A 10 mV DC
10
10
Gold-clad silver
8
5
(3 to 24 V DC)
(48 V DC)
4 Form C
5
280 mW
400 mW
200 mW
400 mW
50 m
2 FORM C RELAY
1 A
LOW PROFILE
.354
9
5
.197
M.B.B.type
+0.4
–0.2
110 V DC
mm
2 Form D
1 A 30 V
200 mW
+.016
–.008
30 W
DC
10
10
—
—
—
inch
7
5
FEATURES
• High sensitivity:
• Surge voltage withstand: 1500 V FCC Part 68
• Sealed construction allows automatic washing
• Self-clinching terminal also available
• M.B.B. contact types available
Characteristics
*
*
Initial insulation resistance*
Initial
breakdown
voltage
FCC surge voltage between open
contacts
Operate time [Set time]*
(at 20 C)
Release time [Reset time]*
(at 20 C)
M.B.B. time*
Temperature rise*
Shock resistance
Vibration
resistance
Conditions for
operation, trans-
port and storage*
(Not freezing and
condensing at low
temperature)
Unit weight
8
9
2 Form C: 140 mW power consumption (single side stable type)
4 Form C: 280 mW power consumption (single side stable type)
M.B.B. time:
Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT
8
Between open
contacts
Between contact
and coil
Between contact
sets
9
2
(at 20 C)
Measuring
condition
Functional*
Destructive*
Functional*
Destructive
Ambient
temperature
Humidity
2 Form C:
4 Form C:
TQ RELAYS
3
4
1
5
7
6
Approx. 3 g
750 Vrms for 1 min.
(Detection current:
–40 F to +158 F
–40 C to +70 C
(B.B.M) type
5 V DC
Standard
176.4 m/s
10 mA)
Min. 1,000 M (at 500 V DC)
at double amplitude of 3 mm
at double amplitude of 5 mm
294 m/s
[Max. 3 ms (Approx. 2 ms)]
[Max. 3 ms (Approx. 2 ms)]
(Detection current: 10 mA)
(Detection current: 10 mA)
Max. 3 ms (Approx. 2 ms)
Max. 3 ms (Approx. 1 ms)
500
—
Min. 10 s
1,000 Vrms for 1 min.
1,000 Vrms for 1 min.
Min. 980 m/s
Approx. 1.5 g
Min. 490 m/s
.106 oz.
5 to 85% R.H.
2
Max. 50 C
2
{30G}, 10 to 55 Hz
1,500 V
{18G}, 10 to 55 Hz
300 Vrms for 1 min.
(Detection current:
2
2
–40 F to +122 F
–40 C to +50 C
.053 oz
{100G}
{50G}
M.B.B.type
Min. 10 s.
10 mA)
—
TQ
TESTING