G6KU-2F-Y DC3 Omron, G6KU-2F-Y DC3 Datasheet - Page 2

RELAY LATCH DPDT 3VDC SMD

G6KU-2F-Y DC3

Manufacturer Part Number
G6KU-2F-Y DC3
Description
RELAY LATCH DPDT 3VDC SMD
Manufacturer
Omron
Series
G6Kr
Datasheets

Specifications of G6KU-2F-Y DC3

Coil Type
Latching, Single Coil
Coil Current
33mA
Relay Type
Telecom
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
1A @ 30VDC
Coil Voltage
3VDC
Control On Voltage (max)
2.25 VDC
Mounting Type
Surface Mount
Termination Style
Gull Wing
Contact Form
DPDT
Power Consumption
100 mW
Contact Carry Current
1 A
Maximum Switching Current
1 A
Contact Configuration
DPDT
Contact Current Max
1A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
3V
Coil Resistance
91ohm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G6KU-2F-YDC3
G6KU-2F-YDC3
G6KU2FYDC3
Z3030
G6K
Application Examples
Telephones, communications equipment, measurement devices, office automation machines, and audio–visual products.
Specifications
Contact mechanism:Bifurcated crossbar Ag (Au-alloy contact)
Enclosure ratings:Fully sealed
Single-side Stable Models
G6K-2F, G6K-2G, G6K-2P
Note:
Single-side Stable Models (Bellcore Version)
G6K-2F-Y, G6K-2G-Y, G6K-2P-Y
Note:
Single-winding Latching Models (Bellcore Version)
G6KU-2F-Y, G6KU-2G-Y, G6KU-2P-Y
Note:
2
Rated voltage
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
Power consumption
Rated voltage
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
Power consumption
Rated voltage
Rated current
Coil resistance
Must set voltage
Must reset voltage
Max. voltage
Power consumption
Coil Ratings
1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.
1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.
1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.
3 VDC
33.0 mA
91 Ω
80% max. of rated voltage
10% min. of rated voltage
150% of rated voltage at 23°C to 70°C
Approx. 100 mW
3 VDC
33.0 mA
91 Ω
80% max. of rated voltage
10% min. of rated voltage
150% of rated voltage at 23°C to 70°C
Approx. 100 mW
3 VDC
33.0 mA
91 Ω
75% max. of rated voltage
75% max. of rated voltage
150% of rated voltage at 23°C to 70°C
Approx. 100 mW
4.5 VDC
23.2 mA
194 Ω
4.5 VDC
23.2 mA
194 Ω
4.5 VDC
23.2 mA
194 Ω
5 VDC
21.1 mA
237 Ω
5 VDC
21.1 mA
237 Ω
5 VDC
21.1 mA
237 Ω
12 VDC
9.1 mA
1,315 Ω
12 VDC
9.1 mA
1,315 Ω
12 VDC
9.1 mA
1,315 Ω
24 VDC
4.6 mA
5,220 Ω
24 VDC
4.6 mA
5,220 Ω
G6K