G6AK-234P-ST-US-DC5 Omron, G6AK-234P-ST-US-DC5 Datasheet - Page 19

RELAY PC MNT DPDT 1A 5VDC

G6AK-234P-ST-US-DC5

Manufacturer Part Number
G6AK-234P-ST-US-DC5
Description
RELAY PC MNT DPDT 1A 5VDC
Manufacturer
Omron
Series
G6Ar

Specifications of G6AK-234P-ST-US-DC5

Coil Type
Latching, Dual Coil
Coil Current
36mA
Relay Type
General Purpose
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
1A @ 30VDC
Coil Voltage
5VDC
Control On Voltage (max)
3.5 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Contact Configuration
DPDT
Contact Current Max
2A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
5V
Coil Resistance
139ohm
Contact Form
2 Form C
Power Consumption
180 mW
Maximum Switching Current
2 A
Contact Rating
0.30 A at 125 VAC, 1 A at 30 VDC
Current, Rating
0.3⁄1 AAC⁄ADC
Function
Latching
Number Of Pins
10
Power, Rating
125⁄60 VA⁄W
Standards
UL, CSA
Termination
Solder
Voltage, Control
5 VDC
Voltage, Rating
125 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G6AK234PSTUSDC5
Z749
G2R
Precautions
I
When mounting a number of relays on a PCB, be sure to provide
a minimum mounting space of 5 mm between the two juxtaposed
relays as shown below.
Cat. No. K013-E1-11B
5 mm min.
Mounting
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
5 mm min.
The above minimum mounting space is necessary due to mutual
thermal interference generated by the relays. This restriction may
be ignored, however, depending on the operating conditions of
the relays. Consult OMRON for details.
There is no restriction on the mounting direction of each relay on
the PCB.
When using this circuit, confirm the set and reset states and then
take into account the circuit constant.
G2R
19

Related parts for G6AK-234P-ST-US-DC5