DS2Y-S-DC12V-R Panasonic Electric Works, DS2Y-S-DC12V-R Datasheet - Page 2

RELAY MINI 12VDC 200MW DIP

DS2Y-S-DC12V-R

Manufacturer Part Number
DS2Y-S-DC12V-R
Description
RELAY MINI 12VDC 200MW DIP
Manufacturer
Panasonic Electric Works
Series
DS2Yr
Datasheet

Specifications of DS2Y-S-DC12V-R

Relay Type
General Purpose
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
2A @ 30VDC
Coil Type
Standard
Coil Current
16.7mA
Coil Voltage
12VDC
Control On Voltage (max)
8.4 VDC
Control Off Voltage (min)
1.2 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
RATING
1. Coil data
Single side stable type
2. Specifications
ds_61005_en_ds2y: 010709J
Contact
Rating
Electrical
characteristics
Mechanical
characteristics
Expected life
Conditions
Unit weight
Nominal coil
Characteristics
1.5V DC
12V DC
24V DC
48V DC
voltage
3V DC
5V DC
6V DC
9V DC
Refer to “6. Usage, Storage and Transport Conditions” in
70%V or less of
nominal voltage
Pick-up voltage
(at 20°C 68°F)
Arrangement
Initial contact resistance, max.
Contact material
Max. switching power
Max. switching voltage
Max. switching current
Max. carrying current
Minimum operating power
Nominal operating power
Insulation resistance (Initial)
Breakdown voltage
(Initial)
FCC surge breakdown voltage between contacts
and coil
Temperature rise (at 20°C 68°F)
Operate time [Set time] (at 20°C 68°F)
Release time [Reset time] (at 20°C 68°F)
Shock resistance
Vibration resistance
Mechanical
Electrical
Conditions for operation, transport and storage*
Max. operating speed (at rated load)
(Initial)
Between open contacts
Between contact sets
Between contact and coil
Functional
Destructive
Functional
Destructive
Drop-out voltage
10%V or more of
nominal voltage
Item
(at 20°C 68°F)
(Initial)
AMBIENT ENVIRONMENT section in Relay Technical
[±10%] (at 20°C 68°F)
Nominal operating
132.7mA
66.7mA
33.3mA
22.2mA
16.7mA
current
8.3mA
6.3mA
40mA
2 Form C
Max. 50 mΩ (By voltage drop 6 V DC 1A)
Ag+Au clad
60 W, 62.5 VA (resistive load)
2 A
3 A
Approx. 98 mW (147 mW: 48 V)
Approx. 200 mW (300 mW: 48 V)
Min. 100MΩ (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
750 Vrms for 1min. (Detection current: 10mA.)
1,000 Vrms for 1min. (Detection current: 10mA.)
1,000 Vrms for 1min. (Detection current: 10mA.)
1,500 V
Max. 65°C with nominal coil voltage across coil and at nominal switching capacity
Approx. 4 ms [approx. 3 ms]
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
Approx. 3 ms [approx. 3 ms]
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Min. 490 m/s
Min. 980 m/s
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10μs.)
10 to 55 Hz at double amplitude of 5 mm
Min. 10
5×10
Ambient temperature: –40°C to +70°C
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
60 cpm
Approx. 4g
220 V DC, 250 V AC
5
(1 A 30 V DC), 10
8
.14oz
2
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
(Half-wave pulse of sine wave: 6 ms.)
[±10%] (at 20°C 68°F)
Coil resistance
5
2,880Ω
7,680Ω
11.3Ω
125Ω
180Ω
405Ω
720Ω
(2 A 30 V DC)
45Ω
–40°F to +158°F
Specifications
Information.
Nominal operating
200mW
300mW
power
Max. applied voltage
(at 50°C 122°F)
nominal voltage
200%V of
DS2Y
2