SPECIFICATIONS
Contact
Notes:
Remarks
* Specifications will vary with foreign standards certification ratings.
*
*
*
*
*
*
*
*
*
*
*
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Rating
Expected
life (min.
operations)
1
2
3
4
5
6
7
8
9
10
11
1 This value can change due to the switching frequency, environmental conditions,
2 The upper limit for the ambient temperature is the maximum temperature that
Measurement at same location as “Initial breakdown voltage” section.
Detection current: 10 mA
By resistive method; nominal voltage applied to the coil; contact carrying current: 2 A.
By resistive method; nominal voltage applied to the coil; contact carrying current: 1 A.
Nominal voltage applied to the coil, excluding contact bounce time.
Nominal voltage applied to the coil, excluding contact bounce time without diode.
Half-wave pulse of sine wave: 6 ms.; detection time: 10 s.
Half-wave pulse of sine wave: 11 ms.; detection time: 10 s.
Half-wave pulse of sine wave: 6 ms.
Detection time: 10 s.
Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT
and desired reliability level, therefore it is recommended to check this with the
actual load. (SX relays are available for low level load switching [10 µA 1 mV DC
– 10 mA 10 V DC])
can satisfy the coil temperature rise. Under the packing condition, allowable
temperature range is from –40 to +70°C
.591
15
Nominal switching
capacity (resistive load)
Max. switching power
(resistive load)
Max. switching voltage
Max. switching current
Min. switching capacity
Nominal
operating
power
Mechanical (at 180 cpm)
Electrical (at 20 cpm)
.291
7.4
.323
8.2
Single side
stable
1 coil
latching
.591
15
1
mm
Standard (B.B.M)
–40°C to
10
(1.5 to 12 V DC)
(1.5 to 12 V DC)
5 10
.291
7.4
DC resistive)
2 A 30 V DC
5
supplementary insulation class
(24 V DC)
(24 V DC)
220 V DC
resistive),
2 Form C
(2 A 30 V DC
HIGH INSULATION RELAYS
inch
.333
200 mW
230 mW
150 mW
170 mW
8.4
60 W
5
type
of EN Standards (EN41003))
2 A
10
(1 A 30 V
8
+158°F.
10 A 10 mV DC
Gold-clad silver
FEATURES
• Approved to the supplementary
insulation class in the EN standards
(EN41003).
The insulation distance between the
contact and coil meet the supplementary
insulation class of the EN41003
standards as required for equipment
connected to the telephone lines in
Europe.
Satisfies the following conditions:
• Clearances: 2.0 mm
• Creepage distance: 2.5 mm
more
100 m
(Conforming to the
10
(1.5 to 12 V DC)
1 A 30 V DC
5
M.B.B.type
110 V DC
(24 V DC)
2 Form D
(1 A 30 V DC
resistive)
250 mW
270 mW
30 W
1 A
10
—
7
.079 inch
Characteristics
*
Initial insulation resistance*
Initial
break-
down
voltage*
Initial
surge
voltage
Temperature rise (at 20 C)
Operate time [Set time]*
(at 20 C)
Release time [Reset time]*
(at 20 C)
M.B.B. time*
Shock
resistance
Vibration
resistance
Conditions for
operation, transport
and storage*
(Not freezing and
condensing at low
temperature)
Unit weight
12
M.B.B. time:
.098 inch
2
or more
12
Between open
contacts
Between contact
and coil
Between contact
sets
Between contacts,
10 160 s
Between contact
and coil, 2 10 s
11
Functional
Destructive*
Functional*
Destructive
or
Ambient
temp. 2
Humidity
5
Measuring
condition
6
1
• 2,000 V breakdown voltage between
contact and coil.
• Outstanding surge resistance.
Surge withstand between open contacts:
1,500 V 10 160 sec. (FCC part 68)
Surge withstand between contact and
coil: 2,500 V 2 10 sec. (Telcordia)
• High contact capacity: 2 A 30 V DC
(Standard type)
• M.B.B. type available
• The use of gold-clad twin crossbar
contacts ensures high contact
reliability.
10
9
RELAYS
Min. 750 m/s
Standard (B.B.M) type
1,000 Vrms for 1 min.
10 to 55 Hz at double amplitude of 3.3 mm
10 to 55 Hz at double amplitude of 5 mm
(Approx. 2 ms)]
(Approx. 2 ms)]
(Approx. 2 ms)
(Approx. 1 ms)
[FCC Part 68]
Max. 50 C*
[Max. 4 ms
[Max. 4 ms
Max. 4 ms
Max. 4 ms
TX-D
–40 C to +85 C
1,500 V
Min. 1,000 M
—
Min. 1,000 m/s
2,000 Vrms for 1 min.
1,000 Vrms for 1 min.
2
Approx. 2 g
2,500 V [Telcordia]
{75 G}*
5 V DC
3
5 to 85%R.H.
500
Min. 10 s
7
–40 F to +185 F
(at 500 V DC)
Min. 500 m/s
.071 oz.
500 Vrms for 1 min.
2
{100 G}
(Approx. 2 ms)
(Approx. 1 ms)
Max. 50 C*
M.B.B.type
Max. 4 ms
Max. 4 ms
Min. 10 s
–
TX-D
2
{50 G}*
4
TESTING
8