G6A-474P-ST20-US-DC12 Omron, G6A-474P-ST20-US-DC12 Datasheet - Page 5

RELAY PC MNT 4PDT 12VDC

G6A-474P-ST20-US-DC12

Manufacturer Part Number
G6A-474P-ST20-US-DC12
Description
RELAY PC MNT 4PDT 12VDC
Manufacturer
Omron
Series
G6Ar

Specifications of G6A-474P-ST20-US-DC12

Coil Type
Standard
Coil Current
16.7mA
Relay Type
General Purpose
Circuit
4PDT (4 Form C)
Contact Rating @ Voltage
2A @ 30VDC
Coil Voltage
12VDC
Control On Voltage (max)
8.4 VDC
Control Off Voltage (min)
1.2 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Contact Configuration
4PDT
Contact Current Max
2A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
12V
Contact Form
4 Form C
Power Consumption
200 mW
Maximum Switching Current
2 A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
G6A474PST20USDC12

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G6A-474P-ST20-US-DC12
Manufacturer:
OMRON
Quantity:
301
Standard Dual Coil Latching 4PDT (G6AK-434P-ST-US, G6AK-474P-ST-US
Dual Coil Latching Low-sensitivity 4PDT (G6AK-434P-ST40-US, G6AK-474P-ST40-US)
Note: The rated current and coil resistance are measured at a coil temperature of 23° C (73° F) with a tolerance of ±10%.
3
5
6
9
12
24
48
3
5
6
9
12
24
48
voltage
voltage
Rated
(VDC)
Rated
(VDC)
106.80
64
53.30
35.60
26.70
13.30
6.70
120
72.50
60
40
30
15
7.50
current
current
Rated
Rated
(mA)
(mA)
28.10
78.10
112.50
253
450
1,800
7,200
25
69
100
225
400
1,600
6,400
resistance
resistance
Coil
Coil
(Ω)
(Ω)
0.02
0.07
0.09
0.18
0.30
1.20
4.40
0.03
0.08
0.11
0.25
0.45
1.80
7.00
Armature
Armature
OFF
OFF
Set coil
Set coil
0.02
0.05
0.08
0.14
0.23
0.82
3.20
0.02
0.06
0.08
0.18
0.32
1.30
5.20
Armature
Armature
Coil inductance
Coil inductance
(ref. value) (H)
ON
(ref. value) (H)
ON
0.02
0.06
0.08
0.18
0.32
1.30
5.20
0.02
0.05
0.08
0.14
0.23
0.82
3.20
Armature
Armature
OFF
OFF
Reset coil
Reset coil
0.03
0.08
0.11
0.25
0.45
1.80
7.00
0.02
0.07
0.09
0.18
0.30
1.20
4.40
Armature
Armature
ON
ON
70% max.
70% max.
pick-up
pick-up
voltage
voltage
Set
Set
% of rated voltage
% of rated voltage
70% min.
70% min.
Low Signal Relay
pick-up
pick-up
voltage
voltage
Reset
Reset
150%
at 23°C
(73°F)
110%
at 70°C
(158°F)
150%
at 23°C
(73°F)
110%
at 70°C
(158°F)
Maximum
Maximum
voltage
voltage
G6A
Approx. 320
Approx. 360
consumption
consumption
Power
Power
(mW)
(mW)