V23154Z1002 Tyco Electronics, V23154Z1002 Datasheet

no-image

V23154Z1002

Manufacturer Part Number
V23154Z1002
Description
RELAY SOCKET PCB SIZE II
Manufacturer
Tyco Electronics
Type
Socketr
Datasheet

Specifications of V23154Z1002

Number Of Positions
16
Mounting Type
Through Hole
Termination Style
PC Pin
Accessory Type
Socket
For Use With/related Products
Cradle Relays, AXICOM
For Use With
V23162B721B110 - RELAY GP 4PDT 2A 24VDC3-1419137-7 - RELAY GP 4PDT 0.2A 24VDC3-1393819-2 - RELAY GP 4PDT 2A 110VDC2-1393819-7 - RELAY GP DPDT 5A 48VDC2-1393819-6 - RELAY GP 4PDT 2A 48VDC2-1393819-3 - RELAY GP 4PDT 0.2A 48VDC1-1393819-9 - RELAY GP DPDT 5A 32VDC1-1393819-7 - RELAY GP 4PDT 0.2A 32VDC1-1393819-6 - RELAY GP 6PST-NO 2A 32VDC1-1393819-3 - RELAY GP 4PDT 0.2A 24VDC1-1393819-2 - RELAY GP 4PDT 2A 24VDC1-1393819-1 - RELAY GP 4PDT 0.2A 24VDC1393819-5 - RELAY GP 6PST-NO 2A 24VDC1393819-2 - RELAY GP DPDT 5A 20VDC1393819-1 - RELAY GP 4PDT 0.2A 20VDC9-1393818-9 - RELAY GP 6PST-NO 2A 20VDC9-1393818-8 - RELAY GP 4PDT 2A 20VDC9-1393818-7 - RELAY GP 4PDT 0.2A 20VDC9-1393818-5 - RELAY GP 6PST-NO 2A 20VDC9-1393818-4 - RELAY GP 4PDT 2A 20VDC9-1393818-2 - RELAY GP 4PDT 0.2A 15VDC9-1393818-1 - RELAY GP 4PDT 2A 15VDC9-1393818-0 - RELAY GP DPDT 5A 12VDC8-1393818-8 - RELAY GP 4PDT 0.2A 12VDC8-1393818-7 - RELAY GP 4PDT 2A 12VDC8-1393818-6 - RELAY GP DPDT 5A 10VDC8-1393818-5 - RELAY GP 4PDT 2A 10VDC8-1393818-0 - RELAY GP DPDT 5A 72VDC7-1393818-8 - RELAY GP 4PDT 0.2A 72VDC7-1393818-7 - RELAY GP 6PST-NO 2A 72VDC7-1393818-6 - RELAY GP 4PDT 2A 72VDC7-1393818-5 - RELAY GP DPDT 5A 125VDC7-1393818-4 - RELAY GP 4PDT 0.2A 125VDC7-1393818-3 - RELAY GP 4PDT 2A 125VDC6-1393817-5 - RELAY GP DPDT 5A 48VDC6-1393817-4 - RELAY GP 4PDT 2A 48VDC5-1393817-7 - RELAY GP DPDT 5A 60VDC5-1393817-6 - RELAY GP 4PDT 2A 60VDC5-1393817-4 - RELAY GP 4PDT 2A 60VDC4-1393817-4 - RELAY GP 4PDT 0.2A 24VDC4-1393817-2 - RELAY GP 6PST-NO 2A 24VDC4-1393817-0 - RELAY GP 4PDT 0.2A 24VDC3-1393817-6 - RELAY GP DPDT 5A 6VDC3-1393817-5 - RELAY GP 4PDT 2A 6VDC3-1393817-4 - RELAY GP 4PDT 2A 6VDC3-1393817-3 - RELAY GP DPDT 5A 12VDC3-1393817-2 - RELAY GP 4PDT 2A 12VDC4-1393816-6 - RELAY GP DPDT 5A 12VAC4-1393816-5 - RELAY GP 4PDT 2A 12VAC4-1393816-4 - RELAY GP DPDT 5A 6VAC4-1393816-2 - RELAY GP 4PDT 0.2A 24VAC4-1393816-1 - RELAY GP 4PDT 2A 24VAC4-1393816-0 - RELAY GP 4PDT 2A 24VAC3-1393816-6 - RELAY GP DPDT 5A 60VAC3-1393816-5 - RELAY GP 4PDT 2A 60VAC3-1393816-4 - RELAY GP DPDT 5A 110VAC3-1393816-3 - RELAY GP 4PDT 0.2A 110VAC3-1393816-2 - RELAY GP 4PDT 2A 110VAC3-1393816-1 - RELAY GP 4PDT 0.2A 110VAC3-1393816-0 - RELAY GP 4PDT 2A 110VAC2-1393816-7 - RELAY GP 4PDT 0.2A 220VAC2-1393816-6 - RELAY GP 4PDT 0.2A 220VAC2-1393816-5 - RELAY GP 4PDT 2A 220VAC2-1393816-4 - RELAY GP 4PDT 0.2A 220VACV23054D1026F104 - RELAY GP DPDT 5A 60VDCV23054D1022F104 - RELAY GP DPDT 5A 45VDCV23054D1019F104 - RELAY GP DPDT 5A 20VDCV23054D1004F104 - RELAY GP DPDT 5A 110VDCV23054D1003F104 - RELAY GP DPDT 5A 220VDC6-1393812-5 - RELAY GP 6PST-NO 2A 60VDC6-1393812-4 - RELAY GP 4PDT 2A 60VDC6-1393812-3 - RELAY GP 6PST-NO 2A 60VDC5-1393812-9 - RELAY GP 4PDT 2A 45VDC5-1393812-8 - RELAY GP 4PDT 2A 45VDC5-1393812-2 - RELAY GP 6PST-NO 2A 24VDC4-1393812-7 - RELAY GP 4PDT 2A 20VDC4-1393812-6 - RELAY GP 4PDT 2A 20VDC3-1393812-9 - RELAY GP 4PDT 2A 110VDC3-1393812-8 - RELAY GP 4PDT 2A 220VDC6-1393809-5 - RELAY GP DPDT 5A 110VDC6-1393809-0 - RELAY GP DPDT 5A 60VDC5-1393809-7 - RELAY GP 4PDT 0.2A 60VDC4-1393809-2 - RELAY GP 4PDT 0.2A 48VDC4-1393809-0 - RELAY GP 6PST-NO 2A 48VDC3-1393809-9 - RELAY GP 4PDT 2A 48VDC3-1393809-4 - RELAY GP 6PST-NO 2A 48VDC2-1393809-3 - RELAY GP 4PDT 0.2A 32VDC2-1393809-2 - RELAY GP 4PDT 2A 32VDC2-1393809-1 - RELAY GP 4PDT 0.2A 32VDC1-1393809-5 - RELAY GP 6PST-NO 2A 32VDC9-1393808-9 - RELAY GP 4PDT 0.2A 24VDC9-1393808-6 - RELAY GP 6PST-NO 2A 24VDC9-1393808-3 - RELAY GP 6PST-NO 0.2A 24VDC8-1393808-4 - RELAY GP 6PST-NO 2A 24VDC7-1393808-4 - RELAY GP 6PST-NO 0.2A 20VDC7-1393808-3 - RELAY GP 4PDT 0.2A 20VDC7-1393808-1 - RELAY GP 6PST-NO 2A 20VDC6-1393808-9 - RELAY GP 4PDT 0.2A 20VDC6-1393808-6 - RELAY GP 6PST-NO 2A 20VDC6-1393808-1 - RELAY GP 4PDT 0.2A 15VDC5-1393808-7 - RELAY GP 6PST-NO 2A 15VDC5-1393808-3 - RELAY GP 4PDT 2A 12VDC5-1393808-0 - RELAY GP 6PST-NO 2A 12VDC4-1393808-6 - RELAY GP 4PDT 2A 10VDC4-1393808-5 - RELAY GP 4PDT 0.2A 10VDC3-1393808-2 - RELAY GP DPDT 5A 5VDC3-1393808-1 - RELAY GP 4PDT 0.2A 5VDC3-1393808-0 - RELAY GP 4PDT 2A 5VDC2-1393808-8 - RELAY GP 4PDT 2A 5VDC1-1393808-7 - RELAY GP 6PST-NO 2A 72VDC1-1393808-6 - RELAY GP 4PDT 2A 72VDC1393808-8 - RELAY GP 6PST-NO 2A 72VDC1393808-4 - RELAY GP DPDT 5A 125VDC1393808-1 - RELAY GP 4PDT 2A 125VDC4-1393807-4 - RELAY GP DPDT 5A 24VDC3-1393807-7 - RELAY GP 4PDT 2A 24VDCV23003B 64B110 - RELAYV23003B 37C110 - RELAYV23003B 37B110 - RELAYV23003B 25B110 - RELAYV23003B 37F104 - RELAYV23054D1020F104 - RELAY GP DPDT 5A 24VDCV23054D 20C110 - RELAY GP 4PDT 2A 24VDCV23054D 20B110 - RELAY GP 4PDT 2A 24VDCV23005B 10F104 - RELAYV23005B 4B110 - RELAYV23005B 4F104 - RELAYV23162B 719F104 - RELAYV23154D 721C110 - RELAYV23154D 721B610 - RELAYV23154D 720W 56 - RELAYV23154D 734B110 - RELAYV23154D 719B110 - RELAYV23154D 717F104 - RELAYV23162H 721B110 - RELAYV23154D 717B110 - RELAYV23154D 716F104 - RELAYV23154D 715F104 - RELAYV23154D 726B610 - RELAYV23154D 712F104 - RELAYV23162B 734B610 - RELAYV23162B 726B110 - RELAYV23154D 722F104 - RELAYV23162B 722B110 - RELAYV23162B 721F104 - RELAYV23162B 721B610 - RELAYV23154D 722B116 - RELAYV23154D 704F104 - RELAYV23154D 720C110 - RELAYV23154D 720F104 - RELAYV23154D 719F104 - RELAYV23154D 716B110 - RELAYV23154D 726F104 - RELAYV23162B 735C410 - RELAYV23154D 720B110 - RELAYV23154D 726B110 - RELAYV23154D 721B110 - RELAYV23154D 722B110 - RELAYV23154D 704B110 - RELAYV23154D 721F104 - RELAY
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
9-1393809-1
AXICOM
Telecom-, Signal and RF Relays
Cradle Relay
Accessories and Mounting
108-98016 • Nov. 07 • Rev. C • ECOC: JM10

Related parts for V23154Z1002

V23154Z1002 Summary of contents

Page 1

... Cradle Relay Accessories and Mounting 108-98016 • Nov. 07 • Rev. C • ECOC: JM10 AXICOM Telecom-, Signal and RF Relays ...

Page 2

... AXICOM Telecom-, Signal and RF Relays Cradle Relay Accessories and Mounting All specifications subject to change. Consult Tyco Electronics for latest specifications. Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, Tyco Electronics does not guarantee that it is error-free, ...

Page 3

... Cradle Relay Accessories and Mounting Sockets with hand solder terminals ROHS compliant (Directive 2002/95/EC) as per product date code 0501. Size I Approx. weight 3.5 g Size III Approx. weight 5.5 g All specifications subject to change. Consult Tyco Electronics for latest specifications. Size II Approx. weight 4.5 g 108-98016 Rev ...

Page 4

... Cradle Relay Accessories and Mounting Sockets with PCB terminals ROHS compliant (Directive 2002/95/EC) as per product date code 0501. Size I Approx. weight 3.5 g Size III Approx. weight 6.5 g All specifications subject to change. Consult Tyco Electronics for latest specifications. Size II Approx. weight 5.5 g 108-98016 Rev ...

Page 5

... N, S and P Socket Size I Size II Dimension a 26.6 32.5 All specifications subject to change. Consult Tyco Electronics for latest specifications. with hold-down spring for cradle relay W with hold-down spring for cradle relay W Size III 38 108-98016 Rev. C Dimensions in mm ...

Page 6

... W Gold plated terminals on request General Data Terminal material Socket material with solder terminals Socket material with PCB terminals Maximum continous current at 70 °C All specifications subject to change. Consult Tyco Electronics for latest specifications. Size Ordering Code I V23154-Z1001 II V23154-Z1002 ...

Page 7

... Experience has shown that under normal operating conditions the minimum spacings specified for cradle relay P are sufficient to prevent cross interference. All specifications subject to change. Consult Tyco Electronics for latest specifications. 108-98016 Rev. C Dimensions in mm ...

Page 8

... This hole is omitted when the mounting hole layout is intended for the socket. Fixing of the socket Direct mounting of relays without socket requires a fixing nut M2.5 DIN 934-m6AU. Ordering code: D00934-A0025-S001 All specifications subject to change. Consult Tyco Electronics for latest specifications. Size II AM 2.5 x ... DIN 84 (Screw length = Dimension a + 3.5 mm) 2 ...

Page 9

... Size II View onto the terminals Fixing of the socket All specifications subject to change. Consult Tyco Electronics for latest specifications. Size III = Earth terminal Hole for mechanical armature actuation, if required Hole for the socket mounting with screw M1.6 AM 1.6 x ... DIN 84 (Screw length = Dimension a + 7.5 mm) 1 ...

Page 10

... Dielectric strength fulfills the requirements according FCC part 68 (1,5 kV – 160 µs). Dimensions approx board space and 11 mm height. All specifications subject to change. Consult Tyco Electronics for latest specifications. D2n Relays 2nd generation non polarized 2 c/o relay for telecom and various other ap- plications ...

Page 11

... E-mail: axicom@tycoelectronics.com Tyco Electronics Paulsternstrasse 26 D-13629 Berlin / Germany Phone +49 30 386 38573 Fax +49 30 386 38575 E-mail: axicom@tycoelectronics.com Tyco Electronics EC Trutnov s.r.o. Komenského 821 CZ-541 01 Trutnov / Czech Republic E-mail: axicom@tycoelectronics.com AXICOM Telecom-, Signal and RF Relays Tyco Electronics Corporation Harrisburg, PA 17105, USA ...