DK1A-PS Panasonic Electric Works, DK1A-PS Datasheet - Page 3

SOCKET RELAY PC MNT FOR DK1A

DK1A-PS

Manufacturer Part Number
DK1A-PS
Description
SOCKET RELAY PC MNT FOR DK1A
Manufacturer
Panasonic Electric Works
Series
DKr
Type
Socketr
Datasheets

Specifications of DK1A-PS

Number Of Positions
4
Mounting Type
Through Hole
Termination Style
PC Pin
Current Rating
10 A
Height
17 mm
Length
23 mm
Mounting
PCB
Resistance, Insulation
1000 Milliohms (Min.)
Socket Type
Single Side Stable
Termination
PCB Pins
Voltage, Breakdown
4000 V (RMS)
Width
15 mm
For Use With/related Products
DK1A Relays
For Use With
255-2376 - RELAY PWR SPST 10A 12VDC LATCH255-2375 - RELAY PWR SPST 10A 5VDC LATCH255-2374 - RELAY PWR SPST 10A 3VDC LATCH255-2060 - RELAY PWR SPST-NO 10A 24VDC PCB255-2059 - RELAY PWR SPST-NO 10A 12VDC PCBDK1A-9V-F - RELAY PWR SPST-NO 10A 9VDC PCBDK1A-6V-F - RELAY PWR SPST-NO 10A 6VDC PCB255-2058 - RELAY PWR SPST-NO 10A 5VDC PCB255-2057 - RELAY PWR SPST-NO 10A 3VDC PCB
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-1101
2. Specifications
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
REFERENCE DATA
1-(1). Maximum operating power (1 Form A)
2-(2). Life curve
(1 Form A 1 Form B, 2 Form A)
Contact
Rating
Electrical
characteristics
Mechanical
characteristics
Expected life
Conditions
Unit weight
Characteristics
1,000
100
100
*2 Wave is standard shock voltage of 1.2 50 s according to JEC-212-1981
*3 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT.
0.1
10
10
1
1
0
actual load.
250 V AC inductive load (cos = 0.4)
30 V DC inductive load (L/R = 7 ms)
DC inductive load
1
AC inductive load
2
(L/R = 7 ms)
(cos = 0.4)
3
10
Arrangement
Initial contact resistance, max.
Contact material
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Nominal operating power
Min. switching capacity (Reference value)*
Insulation resistance (Initial)
Breakdown voltage
(Initial)
Surge breakdown
voltage*
Temperature rise (at 65 C
Operate time [Set time] (at 20 C
Release time [Reset time] (at 20 C
Shock resistance
Vibration resistance
Mechanical
Electrical
Conditions for operation, transport and storage*
Max. operating speed (at rated load)
Contact voltage, V
Contact current, A
4
250 V AC resistive load
30 V DC resistive load
5
2
6
AC resistive load
100
DC resistive
load
7
8
9 10
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Between open contacts
Between contact and coil
between contacts and coil
Functional
Destructive
Functional
Destructive
1,000
Item
149
F)
68
68
1-(2). Maximum operating power
(1 Form A 1 Form B, 2 Form A)
3-(1). Operate/Release time (1 Form A)
Tested sample: DK1a-24V, 5 pcs.
F)
F)
1
0.1
10
5
1
9
8
7
6
5
4
3
2
1
0
3
80
DC inductive load
AC inductive load
90
(L/R = 7 ms)
10 A 250 V AC, 10 A 30 V DC
Max. 40 C (By resistive method, nominal voltage applied to the coil; max. switching current)
Release time
(with diode)
Operate time
Release time
(cos = 0.4)
Au-flashed AgSnO
10
(Nominal voltage applied to the coil, excluding contact bounce time.) (without diode)
Coil applied voltage,%V
250 V AC, 125 V DC
10
Contact voltage, V
Approx. 5 g
2,500VA, 300 W
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Min. 98 m/s
1 Form A
110
Measurement at same location as “Initial breakdown voltage” section.
(Nominal voltage applied to the coil, excluding contact bounce time.)
10 A
10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10 s.)
AC resistive load
DC resistive
100
120
load
.18 oz
Max.
Min.
Max.
Min.
x
Max.
x
Min.
Ambient temperature: –40 C to +65 C
x
Min. 10
Min. 980 m/s
Max. 10 ms (Approx. 5 ms) [10 ms (Approx. 5 ms)]
2
2
Max. 8 ms (Approx. 3 ms) [10 ms (Approx. 3 ms)]
130
1,000 Vrms for 1min. (Detection current: 10mA.)
4,000 Vrms for 1min. (Detection current: 10mA.)
(Half-wave pulse of sine wave: 11 ms; detection time: 10 s.)
type
Max. 30 m (By voltage drop 6 V DC 1A)
10 to 55 Hz at double amplitude of 3 mm
1,000
5
140
(resistive load, at 20 cpm, at rated capacity)
Min. 1,000M
8 A 250 V AC,8 A 30 V DC
2
Min. 5 10
(Half-wave pulse of sine wave: 6 ms.)
250 V AC, 125 V DC
1 Form A 1 Form B
Approx. 6 g
2,000 VA, 240 W
10,000 V (Initial)
10m A 5 V DC
Specifications
2-(1). Life curve (1 Form A)
3-(2). Operate/Release time
(1 Form A 1 Form B, 2 Form A)
Tested sample: DK1a1b-12V, 5 pcs.
200 mW
20 cpm
7
8 A
1,000
(at 300 cpm)
100
(at 500V DC)
10
1
9
8
7
6
5
4
3
2
1
0
.21 oz
0
Au-flashed AgNi type
250 V AC inductive load (cos = 0.4)
30 V DC inductive load (L/R = 7 ms)
80
Operate time
1
–40 F to +149
2
90
Release time
3
Coil applied voltage,%V
250 V AC resistive load
30 V DC resistive load
10
8 A 250 V AC,8 A 30 V DC
Contact voltage, V
Release time
(with diode)
4
250 V AC, 125 V DC
Approx. 6 g
5
2,000 VA, 240 W
110
6
F,
2 Form A
120
8 A
7
Max.
Max.
Min.
Max.
Min.
x
Min.
x
x
8
.21 oz
130
9 10
DK
140

Related parts for DK1A-PS