AQY210KSZ Panasonic Electric Works, AQY210KSZ Datasheet - Page 4

RELAY OPTO SPST 120MA 4 SOP T/R

AQY210KSZ

Manufacturer Part Number
AQY210KSZ
Description
RELAY OPTO SPST 120MA 4 SOP T/R
Manufacturer
Panasonic Electric Works
Series
PhotoMOS™ AQYr
Datasheets

Specifications of AQY210KSZ

Circuit
SPST-NO (1 Form A)
Output Type
AC, DC
On-state Resistance
35 Ohm
Load Current
120mA
Voltage - Input
1.13VDC
Voltage - Load
0 ~ 350 V
Mounting Type
Surface Mount
Termination Style
Gull Wing
Package / Case
4-SOP
Input Type
DC
Input Voltage (max)
1.5V
Output Voltage (max)
350V
Input Current (max)
50mA
Output Current
120mA
Isolation Voltage
1.5kV
Circuit Arrangement
1 Form A
Package Type
SOP
Output Device
MOSFET
Pin Count
4
Mounting
Surface Mount
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Rad Hardened
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-1432-2
AQY210KSZ

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AQY210KSZ
Manufacturer:
Panasonic
Quantity:
12 000
What is short circuit protection latch type?
When the load current exceeds
specifications, the short circuit protection
function kicks in and completely cuts off
the load current, thus turning off the relay.
The short circuit protection inside the
PhotoMOS relay instantaneously
(typ. 50 µs) and completely cuts of the
load current.
This protects any circuits that follow the
PhotoMOS relay from excess current.
There is almost no heating of the
PhotoMOS relay, which prevents it from
becoming damaged. To restore the
function of the relay turn off the input
current and then turn it back on.
In order to operate the short circuit
protection function, ensure that the input
current is at least I
F
= 5 mA.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
GU SOP 1 Form A Short Circuit Protection (AQY210KS)
Output voltage and output current
characteristics
V-I characteristics of PhotoMOS relay
with short circuit protection circuit
Operation chart
Relay input
current
Relay output
current
5mA
120mA
0
0
Output voltage
Normal relay operation
Occurrence of
short circuit current
Detection time
(approx. 50 µs)
Abnormal current
The short circuit current
detection device latches
when the relay is off.
The relay operates normally
when the input current is reset.
If the output section shorts even after
the input current is reset, it will latch
when the short circuit current is
detected again and the relay turns off.

Related parts for AQY210KSZ