RELAY OPTO 2 CHANNEL NC/NC 8-DIP

LBB110

Manufacturer Part Number
LBB110
Description
RELAY OPTO 2 CHANNEL NC/NC 8-DIP
Manufacturer
Clare
Series
LBB, OptoMOS®r
Datasheet

Specifications of LBB110

Circuit
DPST (2 Form B)
Output Type
AC, DC
On-state Resistance
35 Ohm
Load Current
120mA
Voltage - Input
1.2VDC
Voltage - Load
0 ~ 350 V
Mounting Type
Through Hole
Termination Style
PC Pin
Package / Case
8-DIP (0.300", 7.62mm)
Input Type
DC
Input Voltage (max)
1.4V
Output Voltage (max)
350V
Input Current (max)
50mA
Output Current
120mA
Isolation Voltage
3750(RMS)V
Circuit Arrangement
2 Form B
Package Type
PDIP
Output Device
MOSFET
Pin Count
8
Mounting
Through Hole
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Rad Hardened
No
Load Voltage Rating
350 V
Load Current Rating
120 mA
Mounting Style
SMD/SMT
Relay Type
Dual Pole
Load Voltage Max
350V
On State Resistance Max
35ohm
Contact Configuration
DPST-NC
Forward Current If
50mA
Relay Terminals
Through Hole
Rohs Compliant
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
CLA174

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LBB110
Manufacturer:
CLARE
Quantity:
4 356
Part Number:
LBB110
Manufacturer:
CPClARE
Quantity:
5 510
Part Number:
LBB110
Manufacturer:
CLARE
Quantity:
20 000
Part Number:
LBB110E
Quantity:
2 000
Part Number:
LBB110E
Manufacturer:
NEC
Quantity:
2 000
Part Number:
LBB110ES
Manufacturer:
VISHAY
Quantity:
40 000
Absolute Maximum Ratings @ 25ºC
Electrical Characteristics @ 25ºC
2
Parameter
Blocking Voltage
Reverse Input Voltage
Input Control Current
Input Power Dissipation
Total Power Dissipation
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
Parameter
Output Characteristics
Load Current
On-Resistance
Off-State Leakage Current
Switching Speeds
Output Capacitance
Input Characteristics
Input Control Current
Input Dropout Current
Input Voltage Drop
Reverse Input Current
Common Characteristics
Input to Output Capacitance
Peak (10ms)
1
2
1
2
Turn-On
Turn-Off
Continuous
Peak
Derate Linearly 1.33 mW/˚C
Derate Linearly 6.67 mW/˚C
If both poles operate simultaneously, then the load current must be derated so as not to exceed the package power dissipation value.
Measurement taken within 1 second of on-time.
1
2
2
1
-40 to +125
-40 to +85
Ratings
3750
350
150
800
50
5
1
Units
mW
mW
V
mA
V
°C
°C
V
A
rms
I
V
P
F
Conditions
L
=5mA, V
=50V, f=1MHz
I
V
I
L
L
t=10ms
I
www.clare.com
=120mA
L
=120mA
V
F
=350V
=5mA
R
=5V
-
-
-
L
=10V
P
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Symbol
C
I
R
I
LEAK
C
LPK
t
t
V
OUT
I
I
I
I
ON
on
off
R
I/O
L
F
F
F
Min
0.4
0.9
-
-
-
-
-
-
-
-
-
-
Typ
0.7
1.2
25
25
3
-
-
-
-
-
-
-
Max
120
350
1.4
35
10
1
3
3
5
-
-
-
Units
LBB110
mA
mA
mA
μA
ms
μA
pF
pF
Ω
V
R07