CL240D10 Crydom Co., CL240D10 Datasheet

RELAY SSR 280VAC/10A3-32VDC ZC

CL240D10

Manufacturer Part Number
CL240D10
Description
RELAY SSR 280VAC/10A3-32VDC ZC
Manufacturer
Crydom Co.
Series
CLr
Datasheets

Specifications of CL240D10

Termination Style
Screw Terminal
Circuit
SPST-NO (1 Form A)
Output Type
AC, Zero Cross
Load Current
10A
Voltage - Input
3 ~ 32VDC
Voltage - Load
24 ~ 280 V
Mounting Type
Chassis Mount
Package / Case
Hockey Puck
Control Voltage Range
3 VDC to 32 VDC
Load Voltage Rating
240 VAC
Off State Leakage Current (max)
7 A
Load Current Rating
10 A
Mounting Style
Panel
Case Color
Black
Relay Type
Solid State
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
On-state Resistance
-
Lead Free Status / Rohs Status
Compliant
Other names
CC1758

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CL240D10
Manufacturer:
Crydom Co.
Quantity:
135
CL Series
PRODUCT SELECTION
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Control Voltage
3-32 VDC
90-280 VAC
Description
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2)
Maximum Load Current [Arms] (3)
Minimum Load Current [mArms]
Maximum Surge Current (50/60Hz, 1 Cycle) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum I² t for Fusing (50/60Hz, 1/2 cycle) [A² sec]
Minimum Power Factor (with Maximum Load)
• Ratings of 5A and10A @ 24-280 VAC
• UL Approved, CE and RoHS Compliant
• AC or DC control
• Zero-crossing (resistive loads) or random-fire (inductive loads) output
CL240D05
CL240A05
5A
24-280
42/50
36/30
5A
600
500
150
1.8
3.0
0.5
7
5
CL240D10
CL240A10
10A
24-280
84/100
48/40
10A
600
500
150
1.5
2.5
0.5
10
7

Related parts for CL240D10

CL240D10 Summary of contents

Page 1

... Maximum I² t for Fusing (50/60Hz, 1/2 cycle) [A² sec] Minimum Power Factor (with Maximum Load) • Ratings of 5A and10A @ 24-280 VAC • UL Approved, CE and RoHS Compliant • control • Zero-crossing (resistive loads) or random-fire (inductive loads) output 5A CL240D05 CL240A05 10A CL240D10 CL240A10 5A 10A 24-280 24-280 600 600 7 7 ...

Page 2

INPUT SPECIFICATIONS (1) Description Control Voltage Range Maximum Reverse Voltage Maximum Turn-On Voltage Minimum Turn-Off Voltage Typical Input Current @ max turn-on voltage Nominal Input Impedance [Ohms] Maximum Turn-On Time [msec] (4) Maximum Turn-Off Time [msec] GENERAL SPECIFICATIONS Description Dielectric ...

Page 3

MECHANICAL SPECIFICATIONS THERMAL DERATE INFORMATION AGENCY APPROVALS Rev. 042110 ...

Page 4

...

Page 5

ANNEX - ENVIROMENTAL INFORMATION ...

Related keywords